Step by Step Programming Instructions
Items
Process steps
Screen Display
Time of Day
Note:
when “12:12” flashes; Time of Day needs to be reset.
1.
Press
to set Time of Day; both
and
will light and the “:” symbol will flash.
2.
Press
, both
and “H" value will flash, press
or
to adjust hour value.
3.
Press
, both
and “H” value will flash, press
or
to adjust minute value.
4. Press
to accept adjustments made. Press
to advance to the next programming phase.
Unit Mode
1. Press
to enter Unit Mode,
and “02” value will flash.
2. Press
or
buttons to choose HU-1 (m3) , HU-2 (gal) or HU-03 (L).
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
Regeneration
Time
Note:
No regeneration time called for in A-02 Control Mode.
1.
Press
to enter Regeneration Time,
and “Hour” value will flash.
2.
Press
or
to adjust the hour value to the desired regeneration time. (24 hour clock)
3.
Press
again,
and “Minute” value will flash, press
or to adjust minute value.
4. Press
to accept adjustments made. Press
to advance to the next programming phase.
Control
Mode
1. Press
to enter Control Mode,
and “01”value will flash.
2. Press
or
to choose A-01 or A-02. A-03 & A-04
Not available
in the United States.
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
Water
Treatment
Capacity
1. Press
to enter Capacity;
gal
,
and
along with the “2500” value will flash.
2. Press
or
to adjust water treatment capacity value (gal or m
3
).
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
Backwash
Time
1. Press
to enter Backwash Time; M,
and
along with “2-10:00” value will flash.
2. Press
or
to adjust the backwash time.
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
Brine & Slow
Rinse Time
1. Press
to enter Brine & Slow Rinse Time,
and
along with “3-60:00” value will flash.
2. Press
or
to adjust the brine time.
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
Brine Refill
Time
Note:
See instructions below to determine brine refill time needed for your size system.
1.
Press
to enter Brine Refill Time, and
along with “4-10:00” value will flash.
2. Press
or
to adjust the brine refill time.
3. Press
to accept adjustments made. Press
to advance to the next programming phase.
MASTER PROGRAMMING
1
7
Calculating Brine Refill Time -
The brine refill time is calculated based on total resin volume. For optimal efficiency… 3.0
gallons of water are used for 9x48 (32,000 grain) system
9x48-
Brine Refill Time: 10 minutes (3.0 gallons/ .3 refill rate = 10) center brine float to 9# salt setting.
Grain Calculation -
A family of 3 people with 20 grains of hardness: Your family of 3 will use approx. 225 gallons of water
per day (3 people x 75 gallons per person). Since the water has 20 grains of hardness, you'll need to treat 4,500 grains of
hardness per day (225 X 20). If you give the softener its full dose of salt, 15 lbs. per cubic foot, you can go about 7 days
before regenerating (32,000/4,500)