MASTER PROGRAMMING

Familiarize with Button 

Configuration:

CALENDAR

CLOCK

TIME

10:15 AM

REMAIN

DAYS 03

TIME

10:15 AM

REMAIN

GAL 1075

TIME

10:15 AM

REMAIN

GAL 1075

TIME

10:15 AM

REMAIN

DAYS 03

REMAIN

GAL 1075

METER

IMMEDIATE

METER

DELAYED

METER

OVERRIDE

PROGRAM LEVEL

USER ACCESS

MASTER (III)

These settings are programmed by the factory. The settings are important for the operation of the valve that should 
only be changed by a qualified person.

FACTORY (II)

These settings are programmed by the factory and should be adjusted when the valve is assembled into a unit or 
system. It contains important settings so the valve will operate properly for the type of system it is intended for. The
settings should only be changed by qualified person.

USER SETTINGS(I)

These settings are programmed when the unit is installed. The settings should only be adjusted by a qualified person.

This function is to accept the values if changed and advance to the next page in 
the menu.

These buttons are used to increase or decrease the value of the settings while in 
the programming mode.

This function is to enter the basic set up information required at the time of 
installation.

Key Pad Configuration:

PROGRAMMING LEVELS

There are 3 levels to the valve program. Master options and Factory options are typically adjusted at the factory. These options link the PCB function with the type of control 

valve and should not be tampered with. Advanced options are used to configure the unit when the valve is assembled to the tank so that it can function as the proper size and 

intended system operation. Settings are the final options chosen when the unit is installed to a specific location.

MAIN DISPLAY OPTIONS

The main display page according to the regeneration mode setting. The display will alternate between the time of day, remaining gallons, and remaining days..

Summary of Contents for WH-HD-IRN-MG-1054

Page 1: ...refully before operation 2 Avoid pinched o rings during installation by applying NSF certified lubricant to all seals provided with install kit 3 This system is not intended for treating water that is...

Page 2: ...DIMENSIONS 5 INSTALLATION UNPACKING INSPECTION 6 BEFORE INSTALLATION 7 PREPARATION INSTALLATION STEPS 8 INSTALLING BRINE TANK 9 WATER SOFTENER INSTALLATION 10 BASIC PRINCIPLES STARTUP INSTRUCTIONS 11...

Page 3: ...f iron manganese sulfur and sediments Damage to pistons seals and or spacers within the control valve are not covered in this warranty due to the harsh environment X X It is recommended to regularly i...

Page 4: ...ystems can achieve Operational efficiency is the actual efficiency after the system has been installed It is typically less than the efficiency due to individual application factors including water ha...

Page 5: ...unit to freezing temperatures Working Pressure 30 125 PSIG 137 861 kPa Voltage 120V 60 Hz Pipe Size 3 4 or 1 OPERATING CONDITIONS SYSTEM DIMENSIONS MODELS A INCHES B INCHES WH HD IRN MG 948 57 9 WH H...

Page 6: ...eady to use them What is included in the box 1 Control Valve 2 Tank 3 Parts Box 4 Owner s Manual 5 Drain Hose Clamp 6 Brine Tank Assembly There are 5 Red clips Please check to make sure you have all o...

Page 7: ...lation only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local plumbing codes s Two adjustable wrenches s Additional tools may...

Page 8: ...ge to the valve 6 Drain Line connection Using Teflon tape screw the 1 2 hose barb and attach o ring into the drain port in the valve Attach drain hose to the hose barb and tighten securely with a hose...

Page 9: ...embly elbow and hand tighten the nut In many cases the brine line already come installed from the factory Leave the other end of the brine line tube inside the brine tank f For installation of brine t...

Page 10: ...ARROWS ON THE BYPASS ASSEMBLY INDICATING DIRECTION OF WATER FLOW CAUTION Never insert drain line directly into a drain sewer line or trap Always allow an air gap between the drain line and the wastewa...

Page 11: ...people is displayed press SET to complete programming TIME 08 27 AM KEYPAD 4 Add Salt to the brine tank 4 Put up to 3 40 lb bags of water softener salt in the brine tank The unit will automatically f...

Page 12: ...rdness forWater where Iron or Manganese is Present From your water analysis Iron x 4 grains of hardness and or Manganese x 8 grains of hardness These numbers can be found on your water analysis report...

Page 13: ...t to break up the bridge This should always be followed up by allowing the unit to use up any remaining salt and then thoroughly cleaning out the brine tank Allow four hours to produce a brine solutio...

Page 14: ...tor assembly should be cleaned or replaced every year depending on the inlet water quality and water usage The seals and spacer cartridge should be inspected cleaned or replaced every year depending o...

Page 15: ...e powerhead from the valve body assembly 6 Replace the powerhead by reverse following the steps in this section Piston Screw Washer 2 X Screws from Powerhead Powerhead Assembly Valve Body Assembly Met...

Page 16: ...CLEAN INJECTOR ASSEMBLY PISTON AND OR BRINE VALVE ASSEMBLY REPLACEMENT 3 2 4 1 1 Follow steps 1 to 6 of powerhead removal 2 Remove four screws from the plate on the valve body 3 Remove the plate from...

Page 17: ...se is determined by the quantity of iron in your water consult your local representative or follow thedirections on the resin cleaner package Res Up Feeders attach to your brine tank and automatically...

Page 18: ...touches the bottom of the bottle Insert the other end of the tube completely into the hole in the brine well cap Automatic feeding will start in a few hours INSTALL RES UP FEEDER IN SQUARE BRINE TANK...

Page 19: ...ettings should only be adjusted by a qualified person This function is to accept the values if changed and advance to the next page in the menu These buttons are used to increase or decrease the value...

Page 20: ...t be changed DELAY SETTINGS The delay settings are used to precisely stop the motor piston in the correct position This value is factory set and should not be changed MASTER OPTIONS LEVEL III Press SE...

Page 21: ...EFILL 11 1 MIN BRINE 60 MIN BRINE 60 MIN RINSE 10 MIN RINSE 10 MIN RINSE 10 MIN REFILL 11 1 MIN REFILL 11 1 MIN REFILL 11 1 MIN REG TIME 12 00 AM BACKWASH 10 MIN RINSE 10 MIN SOFTENER MODE FILTER MODE...

Page 22: ...0 15 AM REG DYS 03 FILTER MODE CAUTION Thevaluesinthispageareforillustrationpurposeand canbechangedbythefactorywithoutnotice Please contactCustomerServicetoconfirmpropersettings CALENDAR CLOCK METER I...

Page 23: ...NS For questions about your Tier1 whole home water system product installation or performance troubleshooting please call Tier1 Technical Support at 1 855 378 9116 Monday Friday 8 am 5 pm central time...

Reviews: