TIDO-149814381-137 2.0
©2018 Tidomat AB
SIDA 5/9
Installation instructions
English
SO-3304
P11
37
0V OUT
Voltage OUT
38
5V OUT
Voltage OUT
Can be used for card reader that re5V.
39
24V OUT
Voltage OUT
P12
40-
41
1-wire
Future function.
DIP
1-5 ON / OFF
Must be set to OFF to act as a Master in a RS485 loop.
7
ON / OFF
Termination and Pull Down. On = Termination ON.
Must be ON when the door controller act as a Master in a RS485
loop.
8
ON / OFF
Pull Up.
Must be ON when the door controller act as a Master in a RS485
loop.
Technical data
Supply voltage
24 VDC
Internal power consumption
28 mA
Temperature range
+5°C till +40°C
Size (WxHxD)
130x57x95 mm
Cabling
Recommended cable for Central unit
ELQXB 4x2x0,5
Cable length to Central unit
200 meters. 500 meters with local power
supply to SO-3304.
Recommended cable for Card reader
ELQXB 4x2x0,5
Cable length to Card reader
15-50 meters. Depends on the card
reader.
Recommended cable for exit button
ELQXB 2x2x0,5
Recommended cable for RS485-loop
FLAQQBR 2x1 + 1x2x0,22.