23
No message on display.
Power has been cut off to the spa.
The control panel will be disabled until power
returns. Time of day will be preserved for 30
days with a battery back-up on EL8000 and
EL 5000 systems. EL1000 and some EL2000
systems reset the time of day on each power-
up. Pool settings are preserved on all systems
“Overheat” - The pool has shutdown. On some
systems, an alarm may sound. One of the sen-
sors has detected 118ºF (approximately 47.8ºC)
at the heater.
DO NOT ENTER THE WATER.
Remove the
spa cover and allow water to cool. Once the
heater has cooled, reset by pushing any but-
ton. If pool does not reset, shut off the power
to the pool and call your dealer or service
organization
“Overheat” - The pool has shutdown. One of
the sensors has detected that the pool water is
110ºF (approximately 43.3ºC).
•
•
DO NOT ENTER THE WATER
. Remove the
pool cover and allow water to cool. At 107ºF
(approximately 41.7ºC), the pool should auto-
matically reset. If pool does not reset, shut off
the power to the pool and call your dealer or
service organization
“Ice” - Potential freeze condition detected.
No action required. The pumps and the blower
will automatically activate regardless of pool
status.
Pool is shutdown. The sensor that is plugged
into the Sensor “A” jack is not working
If the problem persists, contact your dealer or
service organization. (May appear temporarily
in an overheat situation and disappear when
the heater cools).
•
•
•