Basic System Features and Functions
Main Board Power Requirements (60Hz)
240VAC, 48A, Class A GFCI-protected service (Circuit Breaker
rating = 60A max.)
4 wires (hot, hot, neutral, ground)
Auxiliary Heater Power Requirements (60 Hz)
240VAC, 60Hz, 24A, Class A GFCI-protected service (Circuit
Breaker rating = 30A max.)
4 wires (hot , hot, neutral, ground.)
•
•
•
•
Main Board Power Requirements (50Hz)
Single Service {3 wires (line, neutral, ground)}
230VAC, 50Hz, 1 - ,16A/32A, (Circuit Breaker rating = 20A/40A
max.
Dual Service {5 wires (line 1, neutral 1, line 2, neutral 2,
ground)}.
230 VAC,, 50Hz, 1 -, 2x 16A, Circuit Breaker rating = 20 max
each service.)
3-Phase Service [5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50Hz, 3N -, 16A, (Circuit Breaker rating = 20A max
each phase line.)
IMPORTANT - Service must include a neutral wire, with a line to
neutral voltage of 230VAC.
Auxiliary Heater Board Power Requirements
Single service {3 wires (line, neutral, ground)}
230VAC, 50Hz, 1 -, 24A, (Circuit Breaker rating = 30A max.)
•
•
•
•
•
•
•
•
•