10
For example, the range is “45-55 percent” of “1” level, bottom value can be modified,
and the default value is 50 percent.
To store the modified setting, press the
“i”
button and turn to the next PAS ratio settings.
After all PAS ratio inputted, hold the
“i”
button for 2 s to confirm and then return to
previous menu. Please refer to
Attached list 2
.
PAS Ratio Interface
◆
Controller Over-current Cut Settings (optional)
CUR represents controller over-current cut settings. CUR value can be changed from
7.0A to 25.0A. The default value is 15A.
To change basic settings, press the
“+”
or the
“-”
button to increase or decrease the
value of the current.
To store a changed setting, hold the
“i”
button and then return to previous menu.
CUR Settings Interface
◆
Power Assistant Sensor Settings (optional)
The Direction of PAS Settings
PAS represents power assistant sensor settings. “run-F” means forward direction,
while “run-b” means back direction. The default value is “run-F”.
To change The Direction of Power Assistant Sensor Settings, press the
“+”
or the
“-”
button to select F or b.
To store a changed setting, press the
“i”
button and then access settings mode of PAS
sensitivity.
Direction of PAS Sensor Settings
The Sensitivity of PAS Settings
Summary of Contents for KD51C