background image

± 0.3°F from 102.2°F to 108.5°F

The tia NC-9900 can measure temperatures below 90°F  (32°C( and 

above 109°F  (42.9°C), but precision is not guaranteed outside this 

range

Longevity: your tia NC-9900 is guaranteed for 40,000 reading

IX.  

WHAT’S INCLUDED

• 

User’s manual 

• 

Warranty registration card

• 

Protective carrying bag

• 

One 9-volt battery

• 

Your tia NC-9900

X.  

TROUBLESHOOTING

Should a problem occur with your

 

tia NC-9900, follow the guidelines below 

to help resolve the issue.  If problem persists, please contact our customer 

service department at [email protected]

• 

Display shows temperature greater than 95°F

Temperature is in Fahrenheit

Change measurement to Celsius

 

Press trigger to activate unit

 

Press “°C” button to change from Fahrenheit to Celsius

• 

Display shows body temperature less than 89.6°F (32°C)

Thermometer is in SURFACE mode giving you a reading of external 

surface temperature

To take internal body temperature, change to BODY mode by:

Press trigger to activate unit

Press and hold “°C” button for approximately 3 seconds until F1 is 
displayed

Press “°F” button once to show F3

Press “M” button to display current setting

Press “°F” button to change from SURFACE to BODY (or vice 

versa)

Press “M” button to select mode

Press trigger to exit

Summary of Contents for NC-9900

Page 1: ......

Page 2: ......

Page 3: ...escription tia NC 9900 V Using your tia VI Settings o Unit of Measure o Alarm Setup o Body or Surface Mode o Total Variation o Laser Light Setup o Memory Data o Battery Changing VII Functions VIII Specifications IX Included with tia NC 9900 X Troubleshooting CONTENTS ...

Page 4: ...not be used outside Do not drop Should a problem occur please contact the store where you purchased your tia Do not attempt to repair device yourself IMPORTANT SAFEGUARDS Do not dismantle MANUFACTURER RESERVES THE RIGHT TO ALTER SPECIFICATIONS WITHOUT PRIOR NOTIFICATION II INTRODUCTION The tia NC 9900 no contact thermometer has been developed with the latest infrared technology which allows tempor...

Page 5: ...ays wait at least 15 seconds one minute is recommended between measurements PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE In order to ensure that accurate consistent temperature measurements are obtained it is essential that each user become familiar with correct operation of the tia NC 9900 Keep in mind that taking someone s temperature is simple yet important Temperature should be taken und...

Page 6: ...lower by 0 5 F 0 8 F 0 3 C 0 4 C than when standing NORMAL TEMPERATURES ACCORDING TO AGE 0 2 years 97 5 F 100 4 F 36 4 C 38 0 C 3 10 years 97 0 F 100 0 F 36 1 C 37 8 C 11 65 years 96 6 F 99 7 F 35 9 C 37 6 C 65 years 96 4 F 99 5 F 35 8 C 37 5 C IV DESCRIPTION OF tia NC 9900 1 Laser pointer lens 2 Infrared Sensor 3 Trigger 4 Battery compartment cover 5 Backlit LCD display 6 Fahrenheit 7 Memory 8 Ce...

Page 7: ... the environment occurs allow your tia NC 9900 to reach current room temperature about 15 20 minutes before using Aim toward the forehead from 2 6 inches 5 15cm away Press the trigger button and temperature is displayed in half a second Note temperature may also be taken from behind the earlobe Allow at least 15 seconds 1 minute is recommended between measurements VI SETTINGS During any setting fu...

Page 8: ...s F2 Press M button to display current setting Press C button to increase threshold by 0 2 F 0 1 C Press F button to decrease threshold by 0 2 F 0 1 C Confirm by pressing trigger Press trigger to exit Note Default value is 1 2 F 0 8 C Manufacturer recommends that you keep this setting Important Reminder Whenever there is a significant change in ambient room temperature please allow the tia NC 9900...

Page 9: ...reen displays F1 o Press F button once to display F3 o Press M button to view current setting o Press F button to change from BODY to SURFACE or vice versa o Press M button to select desired choice of mode o Press trigger to exit 5 Laser and Backlight controls Press trigger to activate unit If laser beam is off press button once to turn back light on only Press button again to also activate laser ...

Page 10: ...ss M button and then C button to view up to the 32 previous readings Note Display shows a count up from 1 to 32 in between temperature displays To view a count down from the 32nd reading down to the most recent follow the same procedure as above but press the F button instead of the C button To clear memory press and hold M button for approximately 3 seconds Press trigger to exit 7 Whenever you ar...

Page 11: ...er use rechargeable batteries in the tia NC 9900 VII FUNCTIONS Specially designed to take the body temperature of a person regardless of the room temperature Quick reliable results as it uses the HEIMMANN infrared detection system Unique beep if temperature is exceeded Stores 32 previous measurements LCD back lit digital screen Data displayed in either Celsius or Fahrenheit Energy saving automatic...

Page 12: ... the aorta via the carotid artery tia NC 9900 thermometer has been designed to produce an instant forehead temperature reading without any contact to the body The efficiency speed and comfort of taking a temperature in this way make it ideal VIII SPECIFICATIONS Normal operating conditions o 50 F 140 F 10 C 40 C o Humidity 80 Power 1 DC 9V battery Size L 6 3 x W 3 94 x H1 57 160mm x 100mm x 40mm We...

Page 13: ...department at cs americocorp com Display shows temperature greater than 95 F oTemperature is in Fahrenheit oChange measurement to Celsius Press trigger to activate unit Press C button to change from Fahrenheit to Celsius Display shows body temperature less than 89 6 F 32 C o Thermometer is in SURFACE mode giving you a reading of external surface temperature o To take internal body temperature chan...

Page 14: ...y to show LO Temperature reading is impeded by the presence of hair please brush away before measuring temperature Temperature reading is impeded by the presence of perspiration please wipe away before measuring temperature Temperature reading is skewed by the presence of air flow please use thermometer away from drafts Measurements are taken too rapidly please wait at least 15 seconds between mea...