9
Charging Wire
Molex Plug
attaches to
Power Supply
Spade Connector,
attaches to end
cap
Ground Terminal
attaches to T bolt
Spade
Connector,
attaches to
end cap
D. ASSEMBLE MOUNTING HARDWARE
With the wires now routed out of the track you will
need to attach the grounding ring. Insert a T bolt
in the track, near the end cap. Slide the Grounding
Ring Terminal (see illustration at right) over the T
nut you just put in. Screw a nut over the T bolt to
tighten down the grounding ring.
The track brackets come in 5 pieces: 1 riser,
2 feet and 2 covers for the feet. Assemble as
illustrated. When installing the T bolts into the
track bracket, make sure to thread the bolts
on, but do not tighten yet.
Riser
5
/
16
-18 x ¾"
Cage bolts
T bolts
(these will fi t into
the track)
Nut for cage bolt
Track Foot
If your track will not be resting on the lower
landing, but will be ending on the lowest step,
insert a second T bolt and bolt the endcap on
from the bottom (see below)
Underside of track
End-
cap
Track
Grounding
Wire
T nuts and
bolts
Provide power to the unit by plugging the
molex plug from the track into the matching
plug from the transformer, then plug the A/C
cord into the other end of the transformer.
Finally, plug in the A/C cord to the wall.
A/C cord
A/C cord
Molex plug coming from transformer
Molex plug coming from transformer
Molex plug coming from track
Molex plug coming from track
Transformer
Transformer
The harness is included with enough wire to cover
all installations. Most likely, you'll have more wire
than you need. DO NOT CUT THE WIRE. Simply
place excess wire inside the track.
Summary of Contents for Citia BOS
Page 21: ...21 I TROUBLESHOOTING FLOWCHART WHEN LIFT WON T RUN ...
Page 22: ...22 ...