background image

S

LEEQ

MAX

 

TLSO

I

NSTRUCTIONS

 

FOR

 U

SE

4615 Shepard Street, Bakersfield, CA 93313, USA

800.432.3466 • ThuasneUSA.com

© 2018 ThuasneUSA All rights reserved.

Warnings

• Carefully read use/care instructions and warnings prior to use.

• If increased pain, swelling, sensation changes, or any adverse reactions are experienced 

while using this product, immediately consult your medical professional.

• For single patient use only.

LIMITED WARRANTY

Thuasne USA warrants to the original purchaser that this product is free 

from defects in materials and workmanship. Normal wear and tear during 

the use of a product is not considered a defect. This Limited Warranty is 

effective from the date of delivery to the original purchaser for up to 6 

months.  

This warranty does not apply if this product;

(1) has been altered in any way;

(2) was not purchased from Thuasne USA or one of its authorized 

distributors;

(3) is not used in accordance with Thuasne USA’s Instructions for Use (IFU).

Under this Limited Warranty Thuasne USA’s sole obligation shall be to 

repair or replace the defective product or associated part(s) at no charge.  

This Limited Warranty does not cover damage as a result of mishandling, 

accidents,improper use or alteration of the product. This warranty is in 

place of all other warranties, either express or implied, including but not 

limited to warranties of merchantability or fitness for a particular purpose. 

Thuasne USA shall not be liable under this or any implied warranty for any 

personal injury, property damage, or special, incidental, or consequential 

damages arising out of, related, or incidental to the use of the product 

even if Thuasne USA has been informed of the prospect of such possible 

loss or damage, unless state law otherwise prohibits this exclusion. User 

should seek advice from their healthcare provider immediately if user 

encounters any kind of adverse reaction related to the use of this product. 

User should consult with their healthcare provider with any questions or 

concerns relating to the proper use of this product for their specific medical 

condition. IMPORTANT- Read all Instructions for Use (IFU) and any other 

associated materials to ensure proper use.

Premium Post-Op/Post-Injury TLSO

PDAC Approved L0464

The rigid back panel, anterior panel, lateral panels and wing shells can be trimmed and heat modified 

to adjust lordosis, add scapula reliefs or create flares. The steel upright can be bent to match 

anatomical contours and the wings can be attached to the Crescent Connectors at up to 5 degree 

angles up or down to accommodate various waist to hip ratios.

INTERIOR SHELLS:

BACK PANEL REMOVAL FOR MODIFICATION:

Separate the cover at the base of the back panel (1). Lift cover (2). Remove the LSO assembly (3).

© 2018 Thuasne USA – All rights reserved.                            L-0005 Rev.D

Care Instructions:

4.0

MODIFICATIONS

5.0

RESET

TRIM

HEAT 

FORM

1

4

REMOVE

SEPARATE

LIFT

Remove plastic panel from material sleeve (4).

2

2

3

REMOVE

When removing the brace, always replace Pull Tabs to ready position (5.1) Lay brace on a flat 

surface then pull each Wing outward to reset the tightening mechanism (5.2).

4.1

4.2

4.3

5.2

5.1

REPLACE

PULL

PULL

ADJUST FOR UNDER AXILLA STRAPPING OPTION

The posterior clip attachment piece can be detached and repositioned to acommodate proper 

postioning for over the shoulder strap placement (A) or the under axilla strapping option (B).

A

B

(Also see Section 3.4 for anterior view)

ANTERIOR

PANEL

WITH SCISSORS

CAUTION:
DO NOT TRIM TOP 

CENTER TABS ON 

ANTERIOR PANEL

Reviews: