Chapter 2: Installation
14
Installing the AC/DC Power Supply
AC alarm output
The AC alarm output provides an alarm signal when the AC/DC Power Supply
cannot deliver the required power from the AC input. This is the case when
•
No AC power is present.
•
The AC fuse is blown.
•
The on/off switch is in the position off.
•
The output is short-circuited or heavily overloaded.
•
An internal error has occurred.
To wire the
AC alarm
output do as follows:
1. Connect the cable to the connector marked AC Alarm according to the
specifications in the table below:
AC ALARM (AC/DC Power Supply)
Connector type
Spring terminal
Wire cross section
Up to 1.5 mm
2
Terminal 1
Closed when ok
Terminal 2
Open when ok
Terminal 3
Common
Terminal 4
GND