Thrane&Thrane TT-3042D Manual Manual Download Page 1

Remote Alarm

TT-3042D

Manual

Summary of Contents for TT-3042D

Page 1: ...Remote Alarm TT 3042D Manual ...

Page 2: ......

Page 3: ...Thrane Thrane Thrane Thrane Remote Alarm TT 3042D Manual Copyright Thrane Thrane A S ALL RIGHTS RESERVED ...

Page 4: ...ment is subject to change without notice and does not represent a commitment on the part of Thrane Thrane A S 1998 Thrane Thrane A S All right reserved Printed in Denmark Document Number TT98 110040 A Release Date 23 June 1998 ...

Page 5: ...esence of flammable gases or fumes Operation of any electrical equipment in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove equipment covers Component replacement and internal adjustment must be made by qualified maintenance personnel Do not replace components with the power cable connected Under...

Page 6: ...This page is intentionally left blank ...

Page 7: ...eration 1 2 1 1 Distress Transmission 1 2 1 2 Status Indicators 2 2 1 3 EGC Indicators 2 2 1 4 Mail Indicator 3 2 1 5 Call Group Reset 3 2 1 6 Audio Indicator 3 2 1 7 Dimmer Control 3 2 1 8 Paper Feed 4 2 1 9 Paper Load 4 2 1 10 Paper Saving 4 2 1 11 Dot Energy 5 2 1 12 Selftest Printout 5 2 1 13 NMEA 0183 Sentence Input 5 2 1 14 NMEA 0183 Sentence Output 6 2 1 15 Serial Print input 6 2 1 16 Remot...

Page 8: ...Table of Contents Table of Contents Page Page ii ii 7Jul98 7Jul98 This page is intentionally left blank ...

Page 9: ...Table of Contents Table of Contents 7Jul98 7Jul98 Page Page iii iii ...

Page 10: ......

Page 11: ...g the TT 3042D Remote Alarm For general information regarding the Arcnet standard please refer to ATA Standards Committee s ANSI ATA 878 1 Local Area Network Token Bus 2 5 MBPS For general information regarding NMEA 0183 standard please refer to National Marine Electronics Association s NMEA 0183 Standard For Interfacing Marine Electronic Navigational Devices Version 1 5 December 1987 or later ...

Page 12: ...ically isolated NMEA 0183 generator output or Serial print input with Ready Busy control Printer Type 112 mm thermal printer with two motors Width 40 char line normal 80 char line compressed Speed 1 l sec normal Character size 9 dot high x 7 dot wide Print direction Normal Reverse logic seek word wrap Paper roll Width 112 mm diam 48 mm length 25 m Supply Voltage 10 5 32 V floating DC Power 2 5W st...

Page 13: ...a login status A build in printer enables hard copy printing of received EGC messages at the Remote Alarm location The TT 3042D includes a distress button allowing direct transmission of distress calls from the unit A navigator with NMEA 0183 output can be connected directly to the TT 3042D for routing of position data back to the Capsat transceiver for automatic update of e g safety and distress ...

Page 14: ...chars line the TT 3042D perform papersaving compression on incoming data by stripping leading spaces and by allowing a maximum of two succeeding blank lines The build in printer can be configured for bottom to top printing and automatic page breaking to allow printouts to be read directly from paperstrip at printout The build in printer is maintenance free printing on 112 mm 4 4 width thermal pape...

Page 15: ...nected to the same transceiver must have different address settings If this is ignored the Arcnet will not operate properly The TT 3042D Remote Alarm is configured by setting an 8 position DIP switch located under the paper inlet To set operating parameters remove paper and turn off power Note Operating parameters are only read at power up or softreset so changes in operating parameters will not c...

Page 16: ... on on 8 Printing Direction 4 on Reverse off off Normal Sounder Timeout 5 on 10 sec Timeout off no timeout off NMEA Aux Port 6 on NMEA 0183 NMEA off Serial data Dot Energy 7 on High High off Normal Printing Width 8 on 40 Chars per line 80 off 80 Chars per line note 1 Jumper W2 and W9 should be in pos 1 2 low in Rx mode to achieve optical isolation else pos 2 3 high note 2 Jumper W2 and W9 must be ...

Page 17: ...gs Jumper Function Fact W1 Watchdog connect Only for debugging Short W2 NMEA 0183 in Optoisolated 1 2 Opto isolated 1 2 2 3 Rx Tx return to GND W3 Remote Turn On 1 2 Enable 2 3 Permanent On 2 3 W8 Arcnet balanced Balanced Open W9 NMEA 0183 out balanced 1 2 Balanced 1 2 2 3 Unbalanced Table 2 Jumper settings Main board ...

Page 18: ...ower is applied it should now be possible for the transceiver to print on the TT 3042D when needed or initiated by the user In case the accompanying Arcnet interconnection cable is not suitable and another cabling has to be made please observe the guidelines given below regarding establishment of an Arcnet Please note that the Arcnet system supported is a twisted pair in bus topology The Arcnet bu...

Page 19: ... cable making up the Arcnet bus should be no longer than 100 meters Minimum spacing between devices connected to the Arcnet bus is 2 meter of cable No more than 8 Arcnet devices including transceiver must be connected to the Arcnet bus In case the NMEA input output or serial input and or the 3 status outputs have to be utilised please refer to section 1 5 2 2 1 0 and 2 1 11 with respect to pin ass...

Page 20: ...3 Ground 4 Remote turn on 2 1 13 1 5 2 X2 I O The pinout of the I O connector 15 pole SubD is listed below Pin Function 1 Distress Urgent 100 Ohm Open Collector 2 Safety 100 Ohm Open Collector 3 Routine 100 Ohm Open Collector 4 Not Connected 5 5V DC 39 ohm 6 GND 7 Arcnet A 8 Arcnet B 9 GND 10 NMEA OUT A or Ready busy Controlled by W9 11 NMEA OUT B 12 NMEA IN A or Serial input 13 NMEA IN B or GND C...

Page 21: ...sat transceiver The Distress button can now be released and the sounder stops The Distress button light starts flashing and continues to do so until a successful distress call has occurred After that the Distress button light turns on If the Distress button light does not turn on and the sounder starts to beep when Distress button is pressed the Remote Alarm is unable to issue the distress request...

Page 22: ...ed the paper diode is flashing in 20 seconds or until OK is pressed before printing is resumed Feeding distance is increased when paper empty is detected 2 1 3 EGC Indicators When receiving an EGC message the corresponding diode turns on and the sounder gives notice When message is acknowledged and the OK button is pressed the diode turns off at all Remote Alarms Distress Urgent The Distress Urgen...

Page 23: ...when Remote Alarm status is changed The sounder also gives a notice when communication status to Capsat transceiver is changed printer error or printer paper empty is detected It also turns on when an alarm request has been send to the transceiver The sounder timeout option set by the DIP switch must not be enabled when the TT 3042D is used as a remote alarm The sounder timeout option must only be...

Page 24: ...pen roll holder and remove remaining roll kernel 2 Press the Paper Feed switch to remove remaining paper 3 Take off the sealing paper on new paper roll and pull out 50 to 60 mm 4 Cut the edge of end of new roll to form an arrow 5 Insert the edge of the paper in the paper feeding slot on printer and press Paper Feed switch After a while the paper edge comes out 6 Insert the paper roll in holder and...

Page 25: ...15 seconds the Remote Alarm is softreset and selftest printout is initiated 2 1 13 NMEA 0183 Sentence Input When configured for NMEA 0183 input output the NMEA 0183 input can be connected to a navigator with a NMEA 0183 output The input is optical isolated and only two wires are to be connected Both inverted TTL 5V 0V and bipolar 15 0V 1V 15V signal levels are accepted The NMEA 0183 input is optic...

Page 26: ...ion and velocity data from the transceiver If the transceiver is equipped with an internal GPS board and has updated position and velocity data these data is transferred to the TT 3042D The TT 3042D then transmits position and velocity formatted as standard NMEA 0183 sentences on the NMEA 0183 port Tx line NMEA 0183 sentences output are GLL VTG and ZDA When using the NMEA 0183 output jumper W9 sho...

Page 27: ... for NMEA data input The port parameters are fixed 2 1 16 Remote Turn On In power saving applications the TT 3042D can be turned on remotely Jumper W3 must then be set in position 1 2 or the Remote Alarm will be turned on permanent To turn on pin 4 on X1 the power connector is connected to battery negative To turn off pin 4 is disconnected form battery negative and left unconnected ...

Page 28: ...2 2 Operation Operation 1 5 1 5 Connectors Connectors Page Page 8 8 7Jul98 7Jul98 This page is intentionally left blank ...

Page 29: ...ault Diagnostics If power diode does not turn on check fuse voltage source and remote turn on setting If power diode is blinking then Arcnet connection to transceiver is failing First check if transceiver is turned on then check the Arcnet cabling if no result then check Arcnet address settings for all units coupled to transceiver ...

Page 30: ...3 3 Fault Diagnostics Fault Diagnostics 3 3 Fault Diagnostics Fault Diagnostics Page Page 2 2 7Jul98 7Jul98 This page is intentionally left blank ...

Page 31: ...4 4 Outline Outline 4 4 Outline Outline 7Jul98 7Jul98 Page Page 1 1 4 4 Outline Outline ...