![Thrane&Thrane Sailor 6081 Installation & User Manual Download Page 17](http://html.mh-extra.com/html/thraneandthrane/sailor-6081/sailor-6081_installation-and-user-manual_1111376017.webp)
Chapter 2: Installation
10
Installing the Power Supply Unit and Charger
Grounding
1. Connect chassis to ship with a cable (minimum wire cross section: 4 mm
2
)
or equivalent. The maximum cable length is 1 m.
2. Connect the drain wire for each cable to the designated GND terminal or
bolt it to the mounting plate as shown below (2.).
3. Ground the Power Supply Unit and Charger to ship, for example at the
screw holding the mounting plate, as shown above (3.).
Connectors and jumpers
•
AC input (on SAILOR 6080 Power Supply)
•
•
2 x DC output (20 A) (X11 and X12)
•
2 x DC output (10 A) (X13 and X14)
•
•
•
Battery temperature sensor S1 (X9)
•
Ethernet interface for monitoring and control (X6)
•
Interface for legacy battery panel and relay output for AC alarm (X5)
•
Relay output for battery voltage alarm (X4)
•
C1, C2, C3 and C4 for Control data
•
P1, P2, P3 and P4 for DC input from SAILOR 6080
•
Cross link interface (X8) when sharing a battery
•
Jumper J500 for cross link interface (X-LINK POWER)
•
Jumper W503 for termination of cross link
(2.)
(3.)
Summary of Contents for Sailor 6081
Page 1: ...INSTALLATION USER MANUAL SAILOR 6081 Power Supply Unit and Charger ...
Page 39: ...Chapter 3 Service and repair 32 Returning units for repair ...
Page 43: ...Chapter 4 Customizing battery settings 36 Changing battery settings ...
Page 61: ...Appendix B Upgrade 54 Upgrading with additional SAILOR 6080 units ...
Page 63: ...Appendix C Approvals 56 Wheelmark ...
Page 68: ...98 130980 A Thrane Thrane A S info thrane com www thrane com ...