4 Installation cables
Console 5000
4-2
1035
4.2
Internal cables overview
Cable No. Cable type
From/To
From/To
Part No.
Signal
Conn.
C7.1.00
PL-PL
RT50xx
RF-Plug
527830
VHF Main RF 1:1
C7.1.01
PL-PL
RT50xx
RF-Plug
527830
VHF DSC RF 1:1
C7.2.00
9-9 pole Sub D
CU51x0 MF/HF
56.123
AUX
1:1
C7.2.01
9-9 pole Sub D
CU51x0 MF/HF
56.123
SCAN-BUS
1:1
C7.2.02
Centronics 25 pole Data Terminal/CU Printer
Supplied
Message
1:1
C7.2.03
2 pole
mini-C Remote
56.121
On/Off
2
C7.2.04
9-9 pole Sub D
Data Terminal
TT-3616C
Supplied
Data
1:1
C7.2.05
Multi Cable
TT-3616C
TT-3043CP-2
37-122732-A
Data
3
C7.2.06
15-15 pole Sub D
RT50xx
37-126527
Option
8
C7.2.07
15-15 pole Sub D
RT50xx
37-126528
SPARC-II
9
C7.2.12
8 pole mini din
Printer
Paper switch
56.122
Control
4
C7.2.14
9-9 pole Sub D
Data Terminal
CU51x0 MF/HF
Supplied
Data
1:1
C7.3.10
Power Cable
Printer
Supplied
DC supply
M
C7.3.11
Power Cable
Data Terminal
Supplied
DC supply
M
C7.3.12
Power Cable
TT-3616C
37-123214-B
DC supply
5
C7.3.13
Power Cable
RT50xx
Supplied
DC supply
M
C8.1.00
PL-PL
RT50xx
RF-Plug
527830
VHF Main RF 1:1
C8.1.01
PL-PL
RT50xx
RF-Plug
527830
VHF DSC RF 1-1
C8.2.00
15-15 pole Sub D
RT50xx
37-126527
Option
8
C8.2.01
15-15 pole Sub D
RT50xx
37-126528
SPARC-II
9
C8.2.02
Centronics 25 pole Data Terminal
Printer
Supplied
Message
1:1
C8.2.03
9-9 pole Sub D
Data Terminal
TT-3616C
Supplied
Data
1:1
C8.2.04
Multi Cable
TT-3616C
TT-3043CP-2
37-122732-A
Data
3
C8.2.05
2 pole
mini-C Remote
56.121
On/Off
2
C8.2.06
8 pole mini din
Printer
Paper switch
56.122
Control
4
C8.3.10
Power Cable
RT50xx
Supplied
DC supply
M
C8.3.11
Power Cable
Printer
Supplied
DC supply
M
C8.3.12
Power Cable
Data Terminal
Supplied
DC supply
M
C8.3.13
Power Cable
TT-3616C
37-123214-B
DC supply
5
C9.2.01
9-9 pole Sub D
Battery Panel
56.123
Batt Sense
1:1
C9.2.02
9-9 pole Sub D
Battery Panel
56.123
Batt Sense
1:1
C9.3.10
Cable, 2 pole
Emg. light/gooseneck
37-126773
DC supply
6
C9.3.11
Cable, 4 pole
Emg. light-dimmer
37-126772
DC supply
7
Notes:
-
Where „From/To“ is left blank, the cable is terminated at the connection board 59-126095.
See relevant internal wiring diagrams, for further information.
-
„Supplied“ = Designates cable that is supplied with a product, and therefore does not have its own
part number.
-
M = Consult the technical manual for the product.
-
Where „Conn.“ is marked with „1:1“, this means that the cable ends are wired pin number 1 to pin
number 1, pin number 2 to pin number 2, and so on for further pin numbers.
Other markings at „Conn.“, refers to cable wiring connection drawings, at the following pages.
2: mini-C Remote, 2 pole:
The two wires are soldered on to two terminals, on an on/off push-button switch.
Summary of Contents for SAILOR 5131A
Page 1: ...TECHNICAL MANUAL SAILOR SYSTEM 5000 GMDSS CONSOLE ...
Page 4: ......
Page 6: ...1 General information Console 5000 1 2 0815 ...
Page 16: ...2 Installation Console 5000 2 10 0815 2 6 Message terminal 37209B 4 screws M4x10 ...
Page 23: ...3 Electrical Installation Console 5000 3 5 3 5 Schematic connection board 0815 ...
Page 24: ...3 Electrical Installation Console 5000 3 6 0815 ...
Page 35: ......
Page 36: ...Thrane Thrane A S info thrane com www thrane com TT 98 127000 THR C Issue C 1035 ...