ThoroughClean D10M-36H Operator'S Manual Download Page 15

 

15 

 

TERMS & CONDITIONS OF SALE: 

 

1.  Work for special build machines will not commence unless a 30% deposit has been made 

and/or official purchase order has been received. 

2.  The final configuration and optional extras are to be agreed to before manufacturing 

commences. An extra cost for changing a model will apply after manufacturing has started 
(if this change leads to extra manufacturing cost or more expensive/extra components) and 
be charged as a variation cost.  

3.  Ownership/title of all equipment remains the property of ThoroughClean until paid for in full. 

Warranty will only be available after this time. 

4.  Warranty is not service. Any calls placed to service equipment will be chargeable to the 

client. Earlier replacement of consumable parts than what is required by the maintenance 
schedule will be at the cost of the client (excluding of course any repairs/replacement of 
parts required under warranty). Please see the LIMITED WARRANTY information 
elsewhere in this document. 

5.  All Rental Spec and Mine Spec model frames will have a hot dip galvanized finish unless 

elsewhere agreed to in a proposal offered to the client. Industrial Spec frames will have a 
painted finish or galvanized finish – the latter usually at extra cost. 

6.  Any additional spares, service kits, nozzle kits, etc are excluded, unless otherwise 

mentioned in the proposal to the client.  

7.  Any extra installation and fitting expenses and all electrical or plumbing work required 

during installation will be at the cost of the client. It is the responsibility of the client to 
provide adequate pressured water supply of potable quality 15% more than the required 
flow of the pressure pump specification, and suitable power supply outlet for electrical units 
where applicable. 

8.  No responsibility will be taken for late delivery day due to unforeseen circumstances. 

Please regard building times for special builds and machines out of stock as estimates only. 

9.  Sale of this unit/s is on an FOB Bundamba, QLD basis unless otherwise agreed to in 

writing in this proposal and it is the responsibility of the client to insure goods in transit. 

10.  Our price quoted is valid for 30 days only unless stated otherwise elsewhere in the quote. 
11.  Where deposits have been paid on special builds, such deposits will in part or in full 

become non-refundable once building has started. Should a customer decide to cancel an 
order - all labour and a re-stocking and administration fee for components will be charged 
to the customer and the balance (if any) repaid to the customer. Any special non-
restockable components will be invoiced to the customer. 

12.  All prices quoted are excluding GST and freight unless otherwise stated.  
13.  All prices quoted does not include installation (where applicable) or training unless 

otherwise stated. 

14.  Installation and training service of $90/h available in Brisbane Metro only. Other sites 

subject to additional travel cost.  

15.  IN NO EVENT SHALL THOROUGHCLEAN BE LIABLE FOR ANY INJURY, EXPENSES, 

PROFITS, LOSS OR DAMAGE, DIRECT, INCIDENTAL, OR CONSEQUENTIAL, OR ANY 
OTHER PECUNIARY LOSS ARISING OUT OF THE USE OR INABILITY TO USE ANY 
PRODUCT DESCRIBED IN THIS DOCUMENT.  

 
 
 
 
 
 
 
 
DISCLAIMER: Although care has been taken to ensure the accuracy, completeness and reliability 
of the information provided, technical features may vary due to ongoing improvements and 
development.  The user of the information agrees that the information is subject to change without 
notice. 

Summary of Contents for D10M-36H

Page 1: ...ical data Specifications 3 Installation Start up 4 Operating Tips Shutting down Regular Checks 6 7 Maintenance Schedule 8 9 Trouble Shooting Guide 10 What can cause expensive damage to your machine 11...

Page 2: ...R NPM1525R NPM1525R NPM1525R Old HAWK pump model HC456 HC456 HC456 HC456 Max Pressure Flow 3625 psi 15 lpm 3625 psi 15 lpm 3625 psi 15 lpm 3625 psi 15 lpm Set up de rated pressure flow 3000 psi 15 lpm...

Page 3: ...l not more If oil need to be topped up use SAE10W40 or SAE 15W40 or SAE30 and top up at the Slave Oil Tank if fitted otherwise on the pump itself Ensure water supply tap on portable machines or tank b...

Page 4: ...gent by spraying from bottom up to avoid streaking using a dual lance and detergent assembly Allow to soak for a few minutes 3 Blast off dirt using high pressure and a bottom up approach 4 Lastly rins...

Page 5: ...n to prevent damage o Automatic dumping of hot water when water temp rises above 63 deg C Worn By Pass Valves Soft Acting By Pass valves should NOT store high pressure water in hose down stream betwee...

Page 6: ...and Refurbish pump Replace Plunger Rod Oil Seals 3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only if required 11 Check By...

Page 7: ...time to replace the seals on the pump using a Seal Kit At the same time also replace the seals on the By Pass Valve using a By Pass kit or if economically viable replace by pass valve By Pass Valves w...

Page 8: ...ocked Cavitation or air in the system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the...

Page 9: ...Piston Seals Worn Cracked Piston Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Wor...

Page 10: ...lost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Page 11: ...s bearings on shafts where water penetration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS...

Page 12: ...cial note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT WARNING TAG AND TAKE THIS TO A MEDICAL PR...

Page 13: ...able loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits to the consum...

Page 14: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Page 15: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Page 16: ...6 38 37 34 26 40 41 42 1 29 33 6 10 9 8 13 12 14 20 19 11 43 44 45 48 31 32 23 16 25 30 15 16 17 18 27 46 47 24 3 28 7 4 2 26 25 23 16 21 22 13 14 11 18 12 5 Hawk NPM1525 serie 2011 NPM1525 pump 2011...

Page 17: ......

Page 18: ...02 00 Valve plate 6 21 0900 30 Valve spring 6 22 0604 05 Valve cage 6 23 1802 03 Hexagonal screw M8x18 8 24 0500 61 Closed bearing housing 1 25 0601 63 O Ring 1 78x60 05 2 26 0200 06 Roller bearing 33...

Page 19: ...Seals 18 mm 1 2600 37 Complete Seals Packing 18 mm 3 2612 42 Plunger 18 mm 3 2600 08 Complete Valve 6 2608 03 Plunger oil Seals 1 2600 75 Complete Manifold 1 3100 13 Connecting Rod Plunger Rod Assy 3...

Page 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Page 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Page 22: ......

Page 23: ...B 25A FUSE 15A E STOP OFF ON START STARTER SOL NEGATIVE R1 WATER R3 R3 WATERFAULT LIGHT R2 OIL ENGINEFAULT LIGHT H M A FUEL SOL OIL OFF ON BURNER R4 FLOW PRESSURE R5 R4 R4 FAN M IGN M START SOL WATERF...

Reviews: