This document is the property of EADS Secure Networks Oy
and should not be copied or circulated without permission.
7
It is necessary to make sure that the radio is not restarted, not even
accidentally.
We recommend that the unit is returned to ecom instruments GmbH
for inspection.
The safety of the unit may be compromised, if, for example:
- there is visible damage to the housing
- the unit has been subjected to excessive loads
- the unit has been improperly stored
- the unit has been damaged in transit
- unit markings or inscriptions are illegible
- malfunctions occur
- permitted limit values have been exceeded.
6
EX-DATA
EC-Type Examination Certificate No.: ZELM 07 ATEX 0347 X
Ex-Designation:
Ex II 2 G Ex ib IIC T4
Approved for:
Zone 1 and 2, device group II, explosion group IIC explosive gases,
vapours or mist, temperature class T4
7
SPECIFICATIONS
Frequency range:
380-400 MHz (RC-12)
410-430 MHz (RC-13)
806-825, 851-870 MHz (RC-21)
Operating voltage:
3.7 V
Protection rating:
IP54
Dimensions (LxWxD):
157 x 57 x 35 mm
Weight: approx.
300g
Battery / power supply:
BLN-Ex, 1400 mAh Li-Poly
Operating time
(standby/RX/TX)
8-17 hours (90/5/5)
Ambient temperature T
a
-20°C ... +50°C
Storage temperature:
-20°C ... +50°C
CE-Designation:
CE
0102