Thorlux Lighting Vandalux Manual Download Page 2

21LFT21894 Issue 5 

PN 2218E Dec 19

1

2

4. MOUNTING OPTIONS

3

IP 65

Conduit Box

- Boitier d’alimentation - Abzweigdose

- Kopplingsbox - Caja de registro - Kabeldoos

- Koblingsboks - Skrzynka przewodowa

IP 65

Conduit Box

- Boitier d’alimentation - Abzweigdose

- Kopplingsbox - Caja de registro - Kabeldoos

- Koblingsboks - Skrzynka przewodowa

CORNER MOUNT KIT 

(OPTIONAL EXTRA)

x4

x4

x4

CORNER MOUNT KIT FIXING CENTRES (SEE TABLE)

31

13

LUMINAIRE LENGTH  CENTRES

680mm 636mm

680mm SMART 

660mm

1250mm 1208mm

1250mm SMART 

1232mm

1600mm 1558mm

1600mm SMART 

1582mm

1

3

2

4

5

IP 65

IP 65

Conduit Entry

Conduit Entrée - Kabeleinführung

- Kabelgenomföring - Entrada de conducto

- kabelwartels - Kable gjennomføring

- Otwór wlotowy

SURFACE MOUNT

CORNER MOUNT

Summary of Contents for Vandalux

Page 1: ... INFILL SECTIONS Sections pleines Verbindungselemente Sezioni infill Lläggssektioner Seccion de relleno Afdekstukken Fyll seksjoner Segmenty wypełniające LENGTH KG SURFACE 1600 13 8 CORNER 1600 12 2 GB Do not stare at operating lamp May be harmful to the eyes FR Ne pas fixer la lampe en fonctionnement DE Vermeiden Sie den direkten Blick auf die Lampe während diese in Betrieb ist IT Si prega di non...

Page 2: ...x Cajaderegistro Kabeldoos Koblingsboks Skrzynkaprzewodowa CORNER MOUNT KIT OPTIONAL EXTRA x4 x4 x4 CORNER MOUNT KIT FIXING CENTRES SEETABLE 31 13 LUMINAIRE LENGTH CENTRES 680mm 636mm 680mm SMART 660mm 1250mm 1208mm 1250mm SMART 1232mm 1600mm 1558mm 1600mm SMART 1582mm 1 3 2 4 5 IP 65 IP 65 Conduit Entry Conduit Entrée Kabeleinführung Kabelgenomföring Entrada de conducto kabelwartels Kable gjennom...

Page 3: ...1 1 1 2 8 9 1 2 7 N L Permanent Live Constant de phase Dauer strom Permanent in tensione 3 Amp 2 x 3 Amp L N M ains In alim entation Netzspannung 220 240V 50Hz N L Permanent Live Constant de phase Dauer strom To Gear Tray accès au boitier d alimentation Zu Geräteträger 5 Max 2 x 2 5mm2 V Hz Scanlight AutoTest N N 3 Amp 3 Amp N Max 2 x 2 5mm2 V Hz AutoTest Motionline 12V d c i Surface Smart 21LFT 1...

Page 4: ...azione Thorlux non accetta nessuna responsabilità per prodotti modificatie per danni causati quale risultato delle modificheapportate agli stessi Importante Sicurezza Prima di eseguire la manutenzione assi curarsi chela rete elettrica sia completamente isolata Scollegare il prodotto prima di eseguire il test d isolamento dell installazione ES Funcionamiento y Mantenimiento El fallo de lampara fuen...

Reviews: