background image

Rev 11 Oct 2018

Page 3

Chapter 2

Safety

Chapter 2

Safety

2.1

Safety Information

For the continuing safety of the operators of this equipment, and the protection of the
equipment itself, the operator should take note of the 

Warnings, Cautions

 and 

Notes

throughout this handbook and, where visible, on the product itself.

The following safety symbols may be used throughout the handbook and on the
equipment itself.

2.2

General Warnings and Cautions

Warning: Risk of Electrical Shock

Given when there is a risk of injury from electrical shock.

Warning

Given when there is a risk of injury to users.

Caution

Given when there is a risk of damage to the product.

Note

Clarification of an instruction or additional information.

Warning

If this equipment is used in a manner not specified in the handbook, the
protection provided by the equipment may be impaired. In particular, excessive
moisture may impair operation.

Spillage of fluid, such as sample solutions, should be avoided. If spillage does
occur, clean up immediately using absorbant tissue. Do not allow spilled fluid to
enter the internal mechanism.

The equipment is for indoor use only.

Warning

To avoid injury never put any part of your body in the gap between the moving
platform and a rigid structure.

Summary of Contents for NR360S

Page 1: ...HA0040T NR360S Motorized 360 Rotation Stage User Guide Original Instructions...

Page 2: ...4 1 Unpacking 8 4 2 Transportation 8 4 3 Electrical Connections 8 4 4 Attaching to a Work Surface 9 4 5 Attaching Components and Devices 9 4 6 Dimensions 10 4 6 1 Table Mounting Plate 10 4 6 2 LNR or...

Page 3: ...ry motion of the stepper motor into rotary motion of the carriage There is a mechanical reduction in this gear assembly that provides one revolution of the carriage for every 66 turns of the stepper m...

Page 4: ...tation NR360SP4 Grooved Carriage Plate This adapter plate provides an easy means to integrate all of the miscellaneous accessories from our fiber launch systems product line These accessories include...

Page 5: ...ctrical shock Warning Given when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruction or additional information Warning I...

Page 6: ...pper Motor Controller via a flying lead terminated in a D type type connector A 3m extension cable PAA613 is also supplied Manual control of the Nanorotator can be achieved by switching off the drive...

Page 7: ...iguration Utility Stage Tab 6 In the Motor field select the serial number of the stepper motor controller to be configured this number can be found on the rear panel of the controller unit 7 In the St...

Page 8: ...inesis Kinesis 3 On start up the Actuator Startup Settings window is displayed This window allows the correct actuator to be selected Fig 3 2 Stage Configuration Window Note In applications where cont...

Page 9: ...ation 4 Select your actuator type e g HS NR360S M 5 Click OK 6 The server reads in the stage and controller information automatically refer to the handbook for the associated controller for more infor...

Page 10: ...base not by the top platform or any attachments to the top platform Do not carry the Nanorotator by the drive actuator Serious damage may occur if excessive force is applied to the drive Caution When...

Page 11: ...s are detailed in Section 4 6 4 5 Attaching Components and Devices Caution To prevent excessive distortion use nylon washers under the heads of the securing screws Accessory Part Number Table Mounting...

Page 12: ...tage mounting plate 4 HOLES 8 0 0 32 THROUGH 6 5 0 26 101 0 3 98 114 0 4 49 25 0 0 98 50 0 1 97 100 0 3 94 10 0 0 39 all dimensions in millimetres inches A A 50 50 1 99 101 0 3 98 114 0 4 49 100 0 3 9...

Page 13: ...acket 68 0 2 68 APERTURE 7 HOLES 7 00 0 28 THROUGH C BORED 11 0 0 43 X 6 5 0 26 DEEP IN TOP FACE 4 HOLES M6 1 4 20 UNC THROUGH 27 0 1 06 39 5 1 56 52 0 2 05 64 5 2 54 77 0 3 03 25 0 0 98 25 0 0 98 92...

Page 14: ...g and adpter plates are available please see Chapter 6 and www thorlabs com for more details PLATE 5 0 0 2 THICK 14 HOLES M3 6 32 UNC THROUGH GROOVE 3 0 0 05 WIDE X 1 70 DEEP 0 12 0 002 WIDE X 0 07 DE...

Page 15: ...ar Ratio 66 1 Limit Switches Mechanical Normally Open Reference Signal Every 360 Motor Type 2 Phase Stepper Accuracy 5 arcmin If used with BSC201 Bidirectional Repeatability 10 arcsec Speed Range 50 s...

Page 16: ...harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with th...

Page 17: ...Rev 11 Oct 2018 Page 15 Chapter 6 Regulatory 6 2 CE Certificate...

Page 18: ...t Thorlabs for more information Waste treatment is your own responsibility End of life units must be returned to Thorlabs or handed to a company specializing in waste recovery Do not dispose of the un...

Page 19: ...Rev 11 Oct 2018 Page 17 Chapter 7 Thorlabs Worldwide Contacts...

Page 20: ...www thorlabs com...

Reviews: