Note
Minimum and Typical LED Output Power (marked *) measured using a MM Fiber with 400 µm
core diameter, 0.39 NA.
All technical data are valid at 23 ± 5°C and 45 ± 15% rel. humidity (non condensing)
1.
M365F1
Color
UV
Dominant Wavelength
365 nm
Minimum LED Output Power
3.0 mW
Typical LED Output Power
4.1 mW
Current for LED Power Test
700 mA
Maximum Current CW
700 mA
Forward Voltage
4.4 V
Line Width (FWHM)
7.5 nm
Typical Lifetime
>10,000 h
2.
M385F1
Color
UV
Dominant Wavelength
385 nm
Minimum LED Output Power
9.0 mW
Typical LED Output Power
10.7 mW
Current for LED Power Test
700 mA
Maximum Current CW
700 mA
Forward Voltage
4.3 V
Line Width (FWHM)
10 nm
Typical Lifetime
>10,000 h