13
Tonearm and Pick-Up Cartridge
Fig. 1
The
tonearm counterweight
has been removed for
shipping. Screw the counterweight onto the rear end of
the tonearm and adjust the
tracking force.
➔
Page 13
The TP 92 tonearm can accommodate most pick-up
cartridges with a distance of 12.5 mm (½ ”) between the
mounting holes.
To connect the pick-up cartridge, push the four colour-
coded cartridge tags onto the cartridge pins.
If the cartridge pins are not colour-coded, connect them
as follows:
R
right channel (signal)
➔
red
G
right channel (earth)
➔
green
L
left channel (signal)
➔
white
G
left channel (earth)
➔
blue