 CAUTION: 

If it is a 12V system, the bottom left corner of the LCD display will show '12V', '24V' system will show 

24V. 

 CAUTION: 

The first step is to connect the battery. If the connection is made correctly, the controller screen will 

light up; otherwise, check whether the connection is correct.

 CAUTION: 

The second step is to connect the solar panel. If sunlight is present and strong enough (the solar 

panel voltage is greater than the battery voltage), the sun icon on the LCD screen is on; otherwise, check whether 

the connection is correct. (It's recommended that the operation be performed under the debugging mode).

 CAUTION: 

The thirds step is to connect the load. Connect the load leads to the controller's load output terminal 

and the current shall not exceed the controller's rated current.

 CAUTION: 

As the controller will generate heat during operation, it's recommended that the controller be 

installed in an environment with good ventilation conditions.

 CAUTION: 

Choose cables with large enough capacity for connection, in case too much loss incurred on the 

lines causes the controller to misjudge.

 CAUTION: 

The controller has a common positive pole inside. if grounding is needed, ground the positive pole.

 CAUTION: 

It's important to fully charge the battery regularly. At least one full charging every month is 

recommended and failure to do so may cause permanent damage to the battery. Only when in-flow energy 

outpaces the out-flow energy can the battery be charged fully. Users shall bear this in mind when configuring the 

system.

 CAUTION: 

Check whether the controller's connection terminals is tightened securely; if not, it may suffer 

damage when large amounts of current pass through.

ERROR CODE LIST

Code on LCD screen

Corresponding error

E0

No error

E1

Battery over discharge

E2

Battery over voltage

E3

Undervoltage warning

E4

Load short circuit

E5

Load overload

E6

Termparture too high inside controller

E8

Charging current too high

E10

Solar panel input voltage is too high

Summary of Contents for THPWM-30

Page 1: ...THOR Manufacturing 7050 W Palmetto Park Rd Suite 15 Boca Raton FL 33433 1 866 955 THOR RD120808...

Page 2: ...SOLAR CHARGE CONTROLLERS SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE Copyright 2021 THOR Manufacturing Instruction Manual and Warranty Information THPWM 30 TH PWM 30 THPWM 60...

Page 3: ...m batteries 5 The product provides overcharge over discharge overload protection as well as short circuit and reverse connection protection 6 Arange of parameter settings and power down saving functio...

Page 4: ...5 In this mode the user can switch the load on or off by the keys no matter whether it s day or night 4 Debugging mode 16 When the solar panel voltage is higher than the light control off voltage swit...

Page 5: ...AUTION The battery contains large amount of energy Therefore in no cases should the battery be short circuited It s recommended that a fuse be serially connected to the battery CAUTION Keep the batter...

Page 6: ...e not operated for 12s the system will automatically return to display the main menu Night time indicator Day time indicator Solar panel indicator Charging current indicator Battery indicator SOC indi...

Page 7: ...oltage overcharge voltage and two adjecent values shall have a difference of greater than 0 5V CHARGINGAND DISCHARGING OVERLOAD PROTECTIONAND RECOVERY TIME In the charging and discharging overload pro...

Page 8: ...STRUCTIONSAND PRECAUTIONS 1 The controller shall be installed securely and its dimensions are as follows External dimensions 164 0 x 103 5 x 47mm Installation dimensions 154 x 85mm 2 Installation hole...

Page 9: ...er be installed in an environment with good ventilation conditions CAUTION Choose cables with large enough capacity for connection in case too much loss incurred on the lines causes the controller to...

Page 10: ...utput The load will be switched on automatically after 10 minutes set by the user The battery icon flashes quickly and there is no output System overvoltage Check whether the battery voltage is too hi...

Page 11: ...30 Days Equalizing charging time 1 H Boost charging interval 2 H Temperature Compensation 3 0mVfC 2V Light control voltage Light control on 5V light control off 6V light control on plus 1V Light cont...

Page 12: ...11...

Reviews: