Assembly
NOTE:
• This appliance is assembled before delivery except feet.
• This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level. This
should be carried out on completion of the gas connection. Refer to the ‘Gas Connection’ section.
• IM will be stated that the appliance shall be installed in such a way that side body surfaces are not accessible in
the installed position.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1.
The Gas Hot Plates do not require an electrical connection, as they function totally on the gas supply only.
2.
It is essential that the gas supply is correct for the appliance to be installed and that adequate supply pressure
and volume are available. The following checks should therefore be made before installation:-
a. Gas Type required for the appliance is shown in the rating label. Check that this is correct for the gas supply
the appliance is being installed for. The gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section of this manual.
Check the gas supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Rating label .The input rate should be checked against the
available gas supply line capacity. Particular note should be taken if the appliance is being added to an existing
installation.
NOTE:
It is important that adequately sized piping runs directly to the connection joint on the appliance with as few
tees and elbows as possible to give maximum supply volume.
NOTE:
Ensure the regulator is converted to the correct gas type that the appliance will operate on. The regulator
outlet pressure is fixed ex-factory for the gas type .
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs so that the
unit is level and at the correct height.
4.
Connect the gas supply to the appliance through the regulator. (refer to the picture of “Install the Regulator”). A
suitable jointing compound which resists the breakdown action of propane must be used on every gas line
connection, unless compression fittings are used.
5.
Check all gas connections for leakages.
Installation
5
W A R N I N G:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Combustible Surface
Non Combustible Surface
Left / Right Hand Side
250mm
0mm
Rear
250mm
0mm