Trouble Shooting
MAIN BURNER TROUBLE SHOOTING – cont’d.:
GAS MANIFOLD ASSEMBLY REMOVAL:
1. Turn-off the pilot.
2. Shut-off the main isolation valve and follow the lock-
out/tag-out procedure.
3. Disconnect the manifold from the gas regulator.
4. Remove the drip tray.
5. Remove the knob and control panel cover.
6. Disconnect the main pipe assy., thermocouple, and
pilot tube assy. from the safety gas valve.
7. Remove the manifold plate mounting screws (left side
and right side of manifold).
8. Remove the manifold mounting screws (left side and
right side).
9. Pull-out the manifold and remove the mounting plate
from the manifold.
10. Re-install the mounting plate on the manifold
replacement part before installation.
Remove the manifold plate
mounting screws (left side)
Remove the manifold plate
mounting screws (right
side)
Remove the mounting
plate from the manifold
20