background image

 

 

 

 

 

2

 

COM0

 

Command contact of the first channel contact closure 

 

 

3

 

NC1

 

The second channel contact closure output 

 

No alarm: the contact is normally­closed (NC)

 

Alarm: the contact is open

 

 

4

 

COM1

 

Command contact of the first channel contact closure

 

 

5

 

­­

 

­­

 

2­ch contact closure input

 

F­M4SDI­2CC­Rx

 

1

 

K0

 

The first channel contact closure input 

 

 

2

 

COM0

 

Command contact of the first channel contact closure

 

 

3

 

K1

 

The second channel contact closure input

 

 

4

 

COM1

 

Command contact of the second channel contact

 

 

 

 

 

 

 

closure

 

 

5

 

­­

 

­­

 

1­ch Bi­Directional  RS232

 

F­M4SDI­1S32

 

1

 

TXA

 

RS422 differential signal A output

 

 

2

 

TXB

 

RS422 differential signal B output

 

 

3

 

RXA

 

RS422 differential signal A input

 

 

4

 

RXB

 

RS422 differential signal B input

 

 

5

 

G

 

Ground

 

2­ch Bi­Directional RS232

 

F­M4SDI­2S32

 

1

 

TX1

 

RS232 signal output 1

 

 

2

 

RX1

 

RS232 signal input 1

 

 

3

 

G

 

Ground

 

 

4

 

TX2

 

RS232 signal output 2

 

 

5

 

RX2

 

RS232 signal input 2

 

 
Note1: The AUX interface of F­M4SDI­Tx and F­M4SDI­Rx are used in pairs, If using a transmitter with an AUX

 

 

 

   

 

 

 

 

   

   

   

 

   

 

option then the receiver must also have this option for the AUX connection to work properly 
 
 

1.1

Rear Panel

 

 

Figure 2­2­1 F­M4SDI Rear Panel 

 

 

Table 2­2­1 F­M4SDI Rear Panel

 

Name

 

Description

 

DC12V

 

DC 12V power input interface 

 

Requires the included 12V power supply 

 

 

Protective ground (PGND) screw 

 

Thor Fiber 2014       TEL:1­800­521­8467       EMAIL: [email protected]       http://www.thorbroadcast.com

 

 

 

Summary of Contents for f-m3sdi

Page 1: ...User Manual F M4SDI 4 Ch Tx Rx HD SDI Fiber Optic Link with RS 485 Aux User Manual Thor Fiber 2014 TEL 1 800 521 8467 EMAIL sales thorfiber com http www thorbroadcast com...

Page 2: ...ION 1 1 OVERVIEW 1 2 FEATURE 1 3 APPLICATION CHAPTER 2 F M4SDI ENCLOSURES 2 1 FRONT PANEL 2 2 REAR PANEL CHAPTER 3 TECHNICAL SPECIFICATIONS Thor Fiber 2014 TEL 1 800 521 8467 EMAIL sales thorfiber com...

Page 3: ...deo Optional upgrades for the auxiliary include bi directional RS 232 422 data bi directional analog audio or contact closure Supported options are indicated by model numbers 1 2 Features Fully compli...

Page 4: ...al Block A RS485 positive terminal B RS485 negative terminal AUX Available Options 2 channel bi directional audio 2 channel unidirectional audio 2 channel contact closure input output 1 channel bi dir...

Page 5: ...activity OFF No serial data is being sent or received Table 2 1 3 AUX interface AUX interface Pin Name Description 2 Ch bi directional audio F M4SDI 2BA Tx Rx 1 AOUT1 Audio channel 1 output 2 AOUT2 Au...

Page 6: ...2 TXB RS422 differential signal B output 3 RXA RS422 differential signal A input 4 RXB RS422 differential signal B input 5 G Ground 2 ch Bi Directional RS232 F M4SDI 2S32 1 TX1 RS232 signal output 1 2...

Page 7: ...600 Quantization grade 24 bits Sample frequency 48KHz Audio input output voltage 2VP P Bandwidth 20Hz 20KHz Total Harmonic Distortion 0 1 RS485 Interface Connector Terminal Block connector Baud rate...

Reviews: