Table 212 Indicators
Name
Description
ALARM (NOP)
Optical signal loss alarm indicator, red.
ON: Optical signal loss is detected at the port.
OFF: the optical port receive normal signal.
POWER (RUN)
Running indicator LED is green. Blinks when operating normally
OFF: Indicates a problem
IN [1
:
2]
The HDSDI input lock indicator, green.
ON: video input normally.
OFF: video input abnormally.
OUT[1
:
2]
The SD/
HDSDI output status indicator LED is green.
ON: Indicates signal output is normal
OFF: Indicates there is no output signal
ACT
RS485 link indicator LED is green.
Blinking: Indicates serial data activity
OFF: No serial data is being sent or received
Table 213 AUX interface
AUX interface
Pin
Name
Description
2Ch bidirectional audio
FM4SDI2BATx/Rx
1
AOUT1
Audio channel: 1 output
2
AOUT2
Audio channel: 2 output
3
G
Ground
4
AIN1
Audio channel: 1 input
5
AIN2
Audio channel: 2 input
2Ch unidirectional audio
FM4SDI2ATx
1
AIN1
Audio channel: 1 input
2
AIN2
Audio channel: 2 output
3
G
Ground
4
Not Used
5
Not Used
FM4SDI2ARx
1
AOUT1
Audio channel: 1 output
2
AOUT2
Audio channel: 2 output
3
G
Ground
4
Not Used
5
Not Used
2ch contact closure output
FM4SDI2CCTx
1
NC0
The first channel contact closure output
No alarm: the contact is normallyclosed (NC)
Alarm: the contact is open
Thor Fiber 2014 TEL:18005218467 EMAIL: [email protected] http://www.thorbroadcast.com