background image

 

 

 

H-4HD-EMS & EMH

 

 

Thor Fiber 2017      Tel: (800) 521-8467      Email: 

[email protected]

 

     

www.thorbroadcast.com

 

 

General 

Clicking  “General”  from  the  menu,  it  will  display  the  interface  as  Figure-7  where  to 

set the network info for the output TS. 

Figure-7

   

 

Save/Restore 

From the menu on left side of the webpage, clicking “Save/Restore”, it will display the 

screen as Figure-8 where to save or restore your configurations. 

 

Figure-8

 

 

To  set  the  max  output  bit 
rate for the ASI MPTS out 

Users  can  copy  a  stream  from 
the IP out streams (1 MPTS & 4 
SPTS) to output through ASI. 

Summary of Contents for H-4HD-EMH

Page 1: ...H 4HD EMH H 4HD EMS H 4HD EMHS 4 Channel SDI HDMI Pro DVB Contribution Encoder For ASI and IPTV User Manual 2017...

Page 2: ...rt of this document may be reproduced in any form without the written permission of Thor Broadcast The contents of this document are subject to revision without notice due to continued progress in met...

Page 3: ...ESCRIPTION 6 CHAPTER 2 INSTALLATION GUIDE 8 2 1 GENERAL PRECAUTIONS 8 2 2 POWER PRECAUTIONS 8 2 3 DEVICE S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING 8 2 4 ENVIRONMENT REQUIREMENT 9 2 5 GROUNDIN...

Page 4: ...t on mirrored BNC terminals The 4 encoded HDMI HD SDI programs will output through ASI and IP ports in MPTS or SPTS This powerful design allows you to distribute up to 1080p program streams in crystal...

Page 5: ...or H 264 encoding 1 19 5Mbps for MPEG 2 encoding Rate Control Mode CBR VBR Audio encoding MPEG1 Layer II MPEG2 AAC MPEG4 AAC Dolby Digital AC3 Sample rate 48KHz Bit rate 64kbps 96kbps 128kbps 192kbps...

Page 6: ...I SDI HDMI SDI 1 5 Appearance and Description Front Panel Illustration LCD window Power supply indicators Power Alarm Switch When only one power supply is connected or one of the power supplies fails...

Page 7: ...EMH HDMI Input Module 1 Program input port 1 2 HDMI Input Module 2 Program input port 3 4 ASI output ports Power Supply Slot Power Switch Grounding Rear Panel H 4HD EMS SDI Input Module 1 Program inp...

Page 8: ...er should be securely fastened do not open the cover of the products when the power is on After installation securely stow away all loose cables external antenna and others 2 2 Power Precautions When...

Page 9: ...ing current limiting resistance 1M Floor bearing should be greater than 450Kg Environment Temperature 5 40 sustainable 0 45 short time installing air conditioning is recommended Relative Humidity 20 8...

Page 10: ...smoothly General rule of them make sure the device is grounded when installing anywhere Always use copper wire When applied correctly the ground must be wrapped well to ensure maximum conduction so i...

Page 11: ...onfig 1 1 Uptime Video Audio Program Info Video in status Service Provider Program name Service ID PCR PID Video PID Program output enable PMT PID Audio PID 4 Network 4 1 NMS 4 2 IP Stream 4 1 1 NMS I...

Page 12: ...ing channel 3 3 General Settings for Main Menu Press LOCK key on the front panel to enter the main menu The LCD will display the following pages where you can configure the parameters for the Thor Enc...

Page 13: ...nus 2 1 or 2 2 you could set the video audio parameters for the 2 HDMI programs respectively Video in Status Enter this menu to check the video input status Video Format The HDMI SDI encoders support...

Page 14: ...Thor Broadcast Encoders offer Low Latency options MODE 1 is the Fastest NOTE The different combination of Video Format Video Bit rate Low Delay Mode the Resolution of signal source and Decoding optio...

Page 15: ...e ranges from 64Kbps to 320Kbps Select one bit rate from the options provided Program Info Enable or disable the program output in the first sub menu and configure the other parameters in the rest sub...

Page 16: ...ID ON ID Set the TS ID and Original Network ID in the 2 submenus The IDs are in hexadecimal form Output Bit rate Set the max output bit rate for the ASI MPTS out Range 0 100 Mbps NIT Insert Insert you...

Page 17: ...e options TVCT CVCT close VCT ASI Output Copy a stream from the IP out streams 1 MPTS 8 SPTS to output through ASI 4 Network Network is divided into 2 parts NMS and IP Stream NMS Submenus under NMS ar...

Page 18: ...ata Enable Null PKT Filter Output IP Output Port Service IP Subnet Mask NMS IP 192 168 000 136 Subnet Mask 255 255 255 000 Gateway 192 168 000 001 MAC Address 201012345678 Reset Password Yes NO Web NM...

Page 19: ...Time out 30 s H 4HD EMS HD Encoder SW x xx HW x xx Choose yes to save settings Press ENTER to confirm Choose yes to restore the device into the last saved configuration Choose yes to restore the devi...

Page 20: ...fault IP of this device is 192 168 0 136 We can modify the IP through the front panel Connect the pc and the device with net cable and use ping command to confirm they are on the same network segment...

Page 21: ...nus Figure 2 Input 1 From the menu on left side of the webpage clicking Input 1 displays the information of the programs 1st 2nd from the SDI inputs TS indicators Green light indicates the TS is norma...

Page 22: ...adcast com Figure 3 This column is for setting the 1st HD SDI input This column is for setting the 2ed HDSDI input program General Settings for the HDMI IN programs User can edit any item listed as ne...

Page 23: ...t on the latency Please refer to the Appendix attached for detailed information For user to turn to refer detailed explanation of terms on this interface Click this button to apply the default setting...

Page 24: ...r 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com IP Output Click IP Output it will display the interface where to configure the output IP stream in MPTS or SPTS that will output...

Page 25: ...CT Click VCT from the menu it will display the interface as Figure 6 where to set the VCT configuration Figure 6 MPTS 4 SPTS for the 4 programs respectively Supports 1 MPTS 4 SPTS IP outputs Click the...

Page 26: ...gure 7 where to set the network info for the output TS Figure 7 Save Restore From the menu on left side of the webpage clicking Save Restore it will display the screen as Figure 8 where to save or res...

Page 27: ...box it will restart the device automatically Figure 9 Update the Device Click Firmware from the menu it will display the screen as Figure 10 Here user can update the device by using the update file C...

Page 28: ...ill display the screen as Figure 11 It displays the network information of the device Here user can change the device network configuration as needed Figure 11 Change Password When user clicks Passwor...

Page 29: ...keyboard LCD while only the device IP address can be noted in the LCD window Backup Load Click Backup Load from the menu Backup Configuration To back up the device configuration file to a folder Resto...

Page 30: ...H 4HD EMS EMH Thor Fiber 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com Application Drawing...

Page 31: ...H 4HD EMS EMH Thor Fiber 2017 Tel 800 521 8467 Email sales thorfiber com www thorbroadcast com...

Page 32: ...ing sure the unit has plenty of ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the AC input within the power supply and ensure it is working the connec...

Page 33: ...800 521 8467 Email sales thorfiber com www thorbroadcast com Chapter 6 Packing List H 4HD EMS or EMH Encoder 1PC User Manual 1PC HDMI SDI Cables 4PCs Power Cord 1PC For Further Tech Support 1 800 521...

Reviews: