background image

Electrak_GX_Installation_Operation_MNUK-0011-01 | 20220218TJ
Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of 
this product for a specific application. All trademarks property of their respective owners. ©2022 Thomson Industries, Inc.

www.thomsonlinear.com

E

UROPE

United Kingdom

Thomson
Office 9, The Barns
Caddsdown Business Park
Bideford, Devon, EX39 3BT
Phone: +44 1271 334 500
E-mail: [email protected]

Germany

Thomson
Nürtinger Straße 70
72649 Wolfschlugen
Phone: +49 7022 504 403
Fax: +49 7022 504 405
E-mail: [email protected]

France

Thomson
Phone: +33 243 50 03 30
Fax: +33 243 50 03 39
E-mail: [email protected] 

Italy

Thomson
Via per Cinisello 95/97
20834 Nova Milanese (MB)
Phone: +39 0362 366406
Fax: +39 0362 276790
E-mail: [email protected]

Spain

Thomson
E-mail: [email protected]

Sweden

Thomson
Estridsväg 10
29109 Kristianstad
Phone: +46 44 590 2400
Fax: +46 44 590 2585
E-mail: [email protected]

SOUTH AMERICA

 

Brazil

 

Thomson 
Av. João Paulo Ablas, 2970 
Jardim da Glória - Cotia SP - CEP: 06711-250 
Phone: +55 11 4615 6300 
E-mail: [email protected]

 

USA, CANADA and MEXICO

Thomson
203A West Rock Road
Radford, VA 24141, USA
Phone: 1-540-633-3549
Fax: 1-540-633-0294
E-mail: [email protected]
Literature: literature.thomsonlinear.com

 

 
ASIA

 

Asia Pacific

 

Thomson 
E-mail: [email protected]  
 

China

Thomson
Rm 805, Scitech Tower
22 Jianguomen Wai Street
Beijing 100004
Phone: +86 400 606 1805
Fax: +86 10 6515 0263
E-mail: [email protected]

India

Thomson 
c/o Portescap India Pvt. Ltd.
Office no. 103, 4TH floor, 
Arena House, Road no.12, 
Marol Industrial Area, Andheri East, 
Mumbai Suburban, Maharashtra, 400093 India 
E-mail: [email protected]

Japan

Thomson
Minami-Kaneden 2-12-23, Suita
Osaka 564-0044 Japan
Phone: +81 6 6386 8001
Fax: +81 6 6386 5022
E-mail: [email protected]

South Korea

Thomson
3033 ASEM Tower (Samsung-dong) 
517 Yeongdong-daero
Gangnam-gu, Seoul, South Korea (06164)
Phone: + 82 2 6001 3223 & 3244
E-mail: [email protected]

Summary of Contents for Electrak GX

Page 1: ...Thomson Electrak GX Electric Linear Actuator Installation Manual Edition 2022 02 www thomsonlinear com...

Page 2: ...as to the suitability of the product for any particular use or purpose For a copy of the entire warranty for this product that is contained in our standard terms and conditions of sale please go to h...

Page 3: ...roduct identification and product label 6 4 2 Terminology 6 4 3 Operation environment 7 4 4 Mechanical installation 7 4 5 Electrical installation 10 5 Technical specifications 13 5 1 General specifica...

Page 4: ...inal packaging supplied by Thomson The temperature during transportation and storage must be between 25 to 65 C 15 to 150 F Avoid shocks to the package If the package is damaged check the actuator for...

Page 5: ...faulty or damaged in any way and notify an appropriate person so that corrective actions can be taken Never open the actuator as that will compromise the sealing and the function of the actuator Ther...

Page 6: ...gnation of the actuator s in question 4 1 2 Units with product label These units have a product label on the the cover tube The label details which model of actuator you have its basic performance dat...

Page 7: ...uator should be considered to ensure it does not create harm 4 4 2 Basic installation considerations 1 Only mount the actuator using the holes in the front and rear adapters Identify the model designa...

Page 8: ...axially 4 4 4 Restraining torque The rear and the front adapter must be fixed by a method that can restrain the torque produced by the extension tube which for Electrak GX is 11 3 Nm 100 lbf in If not...

Page 9: ...wind input hexagon socket a using a 6 mm hexagon key b 4 The maximum torque required to move the extension tube at the fully rated actuator load using the hand wind is typically 1 5 2 5 Nm 13 22 in l...

Page 10: ...r leads and the power source must be of sufficient size The sufficient size is determined by calculations based on the supply voltage current draw length of the cables ambient temperature and local re...

Page 11: ...L1 When reaching the mechanical end of stroke in any direction the built in slip clutch will engage and thus stop the extension tube movement in that direction The clutch can also be engaged during mi...

Page 12: ...ctive of the reason 4 6 6 Installation of the feedback potentiometer optional feature The potentiometer output has 0 ohm between grey and yellow leads when the actuator is fully extended Electrical Sp...

Page 13: ...5 max dynamic load motor auto reset thermal switch Weight Ordering stroke S in 2 4 6 8 10 12 14 16 18 20 22 24 Weight acme screw models kg 4 4 4 6 4 8 5 0 5 1 5 3 5 5 5 6 5 8 5 9 6 1 6 2 lbf 9 7 10 1...

Page 14: ...torque Nm lbf in 11 3 100 Protection class static Dxxx xxx5 xxMxN Dxxx xxx5 xxMxK IP66 IP66 and IP69K Electrical Specifications Input voltage D12 D24 D36 D48 D90 Vdc 12 24 36 48 90 Input voltage tole...

Page 15: ...12 0 60 0 47 15 11 0 60 043 15 9 0 60 0 35 Stroke S length Axxx xxx5 06 Axxx xxx5 08 Axxx xxx5 10 Axxx xxx5 12 Axxx xxx5 14 Axxx xxx5 16 Axxx xxx5 18 Axxx xxx5 20 Axxx xxx5 22 Axxx xxx5 24 in 6 8 10 1...

Page 16: ...mm 06 6 inch 152 4 mm 08 8 inch 203 2 mm 10 10 inch 254 0 mm 12 12 inch 304 8 mm 14 14 inch 355 6 mm 16 16 inch 406 4 mm 18 18 inch 457 2 mm 20 20 inch 508 0 mm 22 22 inch 558 8 mm 24 24 inch 609 6 mm...

Page 17: ...k GX 3 400 Vac 1100 N acme 30 mm s A42C20A5 Electrak GX 3 400 Vac 1100 N acme 15 mm s A42C05B5 Electrak GX 3 400 Vac 1100 N ball 61 mm s A42C10B5 Electrak GX 3 400 Vac 2250 N ball 30 mm s A42C20B5 Ele...

Page 18: ...anstad Phone 46 44 590 2400 Fax 46 44 590 2585 E mail sales scandinavia thomsonlinear com SOUTH AMERICA Brazil Thomson Av Jo o Paulo Ablas 2970 Jardim da Gl ria Cotia SP CEP 06711 250 Phone 55 11 4615...