1.6 Main Parts
The main unit comes with two current clamps (one red and one black) and one voltage detection line. Connect the
three-pin terminal of the voltage detection line to the “voltage detection” terminal on the back panel of the main unit.
The terminals of the red current clamp are connected to the red terminal block on the back panel, and the terminals of
the black current clamp are connected to the black terminal block on the back panel. Note: It is strictly forbidden to
reverse connection!
1.7 Operation Instruction
Touch screen for all operation
1.8 Wiring
Activation, charge/discharge wiring:
Connect the current/voltage clamps with the battery positive/negative
poles: Black clamp to negative pole, red clamp to the positive pole. (Note: the positive and negative poles are
strictly prohibited to be reversed connection). If the current clamp is reversed, it will cause serious damage to the
instrument. If the voltage clamp is reversed connection, the instrument cannot be operated normally, at the same
time, the instrument will prompt the user to convert the (voltage) clamps, but it will not cause damage to the
instrument.
Current clamp reversed connection not allowed to battery poles; otherwise the instrument
will be seriously damaged.