THOMSON DFT-6900 User Manual Download Page 4

DFT-6900 Battery Activator Instruction Manual

 

Chapter 1 Overview

 

1.1

 

Applications 

 

DFT-6900  is  a  compact  unit  for  daily  maintenance  of  single  cell,  especially  for  old  cells.  It  plays  three  roles:  charge, 

Discharge  and  activator,  which  will  facilitate  your  maintenance  for  batteries.  These  three  functions  could  be  used 

individually or comprehensively. When used comprehensively, lag-out battery will experience low-volt constant current 

charging  and  discharging  singly  or  in  multi-circles  (1~99).  By  activating  the  disabled  active  material  on  battery 

electrode plate, it amends the battery malfunction caused by chemical failure and thus boosts the capacity of old battery. 

Activation curve and certain parameters (e.g.: voltage and resistance) will display on screen as activation ends.   

Battery  activation  is  very  significant  for  resources  utilization  and  efficiency  increasing.  However,  it  is  important  to 

know  that  not  all  weak  batteries  could  be  activated  by  DFT-6900.  It  can  only  amend  the  weak  batteries  whose  bad 

condition is caused by chemical malfunction instead of physical failure such as short-circuit of electrode plate.   

 

1.2 Functions 

● 

Charge, discharge, activation and curve indication functions: 

The  Tester  will  record  the  battery  voltage  and  current  curve  trends  during  charging,  discharging  and  activation.  The 

curve  can  be  displayed  after  test.  The  right  side  of  the  screen  shows  the  charge  (discharge)  curve,  and  the  left  side 

shows  the  charge  (discharge)  or  activation  parameters,  including:  voltage  (current)  indicating,  charge  (discharge) 

current, charge (discharge) cutoff voltage, test duration

.

 

● Data Review 

During the charging (discharging) or activating operation, after test interrupted for some reason, you can choose 

whether  to  view  the  data.  While  viewing  the  data,  press  the  left  or  right  button  to  view  related  data  and  curve 

trends. 

● Data Management 

This feature allows the user to manage the battery's measured data, including data uploads and curve playback. 

● System Upgrade 

This feature allows users to perform online software upgrades. 

1.3 Characteristics 

 

Using  the  latest  online  programmable  CPU,  users  can  use  the  microcomputer  to  update  the  instrument 

software to continuously improve the performance of the instrument.

 

 

Modular structure, reasonable design and reliable operation.

 

 

Comprehensive  measurement  and  accurate  display  of  battery  voltage,  current,  charge  (discharge)  and 

activation results and waveforms. 

 

Powerful, it can charge (discharge) the battery separately, and charge and discharge continuously for several 

times (not more than 99 times).

 

 

English menu operation, easy to learn and use.

 

 

The data stored in Tester can be transferred to computer and managed by the PC software. 

 

The  PC  data  management  software  can  analyze  the  data  of  battery  charge  (discharge)  and  activation,  and 

Summary of Contents for DFT-6900

Page 1: ...DFT 6101 Battery Impedance Tester Instruction Manual DFT 6900 Battery Activator Users Manual THOMSON TECH CO LTD www thomsontesting com...

Page 2: ...on Instruction 5 1 8 Wiring 5 Chapter 2 Functions operations 6 2 1 Discharge 6 2 2 Charge 7 2 3 Activator 8 2 3 1 Activator Setting Interface 8 2 3 2 Activating Process 8 2 4 Data Management 8 2 4 1 D...

Page 3: ...ct operation of the instrument 1 To avoid electrical shock or fire read these precautions first before using the unit 2 Except as explained in this manual do not attempt to service this equipment your...

Page 4: ...ing and activation The curve can be displayed after test The right side of the screen shows the charge discharge curve and the left side shows the charge discharge or activation parameters including v...

Page 5: ...via a U disk By transmitting the data to the PC the battery quality can be monitored for a long time Through the analysis of the battery operating status data various problems which affect the battery...

Page 6: ...ion 1 7 Operation Instruction Touch screen for all operation 1 8 Wiring Activation charge discharge wiring Connect the current voltage clamps with the battery positive negative poles Black clamp to ne...

Page 7: ...e Click Discharge to enter parameters setting It is necessary to set six parameters battery number battery type rated capacity cutoff voltage discharge current and discharge duration Set the discharge...

Page 8: ...rged capacity the charged time and the stop parameters Note 1 The cut off voltage set in the parameter setting is to prevent the battery from over charging discharging which leads to battery damaged C...

Page 9: ...battery The activation settings interface is as follows After clicking the up and down direction keys to set the Cycle No you can set the parameters of each activation by clicking the page up and page...

Page 10: ...e U disk first and the green U symbol will be displayed in the upper right corner of the menu Note U disk read and writes error 1 U disk plugged in properly 2 It is strongly recommended that users use...

Page 11: ...2 4 4 Data Formatting In the data management menu click the Format option to delete all data 2 5 System setting In the main menu interface click System Settings to enter the system management interfa...

Page 12: ...he U disk to Tester After the software update is completed the Tester enters the boot interface and can perform normal operation 2 5 3 Language Enter the System Settings menu page click the Language S...

Page 13: ...ents or alcohol as they can deform or discolor the Tester and the accessories 3 1 2 Clamps Maintenance Clean Clean the main unit and its accessories with damp cloth and a mild soap 3 2 Storage After u...

Page 14: ...e N cycles to prolong the time Example If the charging required time is 28 hours set the activation cycle 2 the first charging time is 18 hours the discharge duration is 0 the second charging time is...

Page 15: ...disk cannot be detected after it is inserted to the PC The U disk may not be well inserted If so reinsert it correctly The U disk may not be in FAT format If so format the U disk And if other problem...

Reviews: