THOMSON 512269 Manual Download Page 7

7

EN

EN

www.mythomson.com

VIDEOPHONE SMART CONNECT

A - SAFETY INSTRUCTIONS

1 - INTRODUCTION

 This video intercom system pairs two modules: 
a receiver-monitor and an easy-to-install and 
use intercom panel. 

Key features: 
• 

 Colour video reception: when a visitor 

touches the intercom panel call button, the 
panel immediately transmits the image to 
the screen and a chime indicates the visitor’s 
presence. 

•   Short-circuit protection
•   Reverse polarity protection
•  Automatic exposure correction: the video 

camera automatically adjusts its exposure to 
match the ambient light conditions. 

•  The LEDs integrated in the intercom panel 

allow  visitors  to  be  identified  without  the 
need for additional lighting.

•  Opening the door and a control system: by 

pressing buttons on the monitor, you can 
control an electric lock and a dry contact for 
an automatic control system (not included).

•  Opening of the gate or the electric strike plate 

depends on the time it takes to read the RFID 
badge.

IMPORTANT: This notice should be read 
carefully prior to installation. In the case of any 
problems, our Hotline technicians are at your 
service to provide you with any information you 
may need.

WARNING: any connection error may cause 
damage to the device and void the warranty.

2 - MAINTENANCE AND CLEANING

Before installing your intercom, it is important 
to check the following points:

•  Do not install in cases of extreme humidity, 

temperatures, corrosion risk or dust.

•  Do not expose to direct sunlight, rain, or high 

humidity.

•  Do not plug the device into a multi-socket 

plug adaptor or extension cord.

•  Be careful not to lose the administrator 

badge (red colour) or your product will be 
locked and the warranty voided.

  Keep it in a safe place. 

•  Do not install near other electronic devices 

such as computers, televisions or video 
recorders.

•  Do not install near acidic chemicals, ammonia 

or sources of toxic gases.

•  Do not clean with abrasive or corrosive 

products. Use a damp cloth with soapy 
water.

•  Unplug the device if it is not being used for an 

extended period of time.

• Do not plug the device into national 

telecommunications installations.

•  The cable between the monitor and intercom 

panel must not be extended. Avoid junctions 
(insulating screw joints, soldered joints, etc.)

3 - RECYCLING

This logo indicates that devices 

which are no longer in use 
must not be disposed of as 
household waste. They are 
likely to contain hazardous 
substances that are 

dangerous to both health and the 
environment. Return the equipment to your 
local distributor or use the recycling 
collection service provided by your local 
council.

Pour en savoir plus : 
www.quefairedemesdechets.fr

Summary of Contents for 512269

Page 1: ...www mythomson com V1 EN Smart video intercom Smart Connect 512269 105 Visitors memory video or pictures 105 Visitors memory video or pictures 2 ...

Page 2: ...ax 25m max 25m max Figure 1 Connection from the intercom panel to the monitor Connecting of the dry contact gate automation or electric strike plate to the intercom panel Cable length Cable length 0 to 25m 5 to 50 m 50 to 100m Section to use Section to use 0 75mm2 0 75mm2 1 5mm2 ...

Page 3: ...3 EN EN www mythomson com VIDEOPHONE SMART CONNECT Figure 2 15V 1 3 2 4 15V 1 3 2 4 100m max Moniteur supplémentaire 512264 25m max 25m max ...

Page 4: ... 10 1 WIRING 10 1 1 Connecting the videophone monitor intercom panel and camera 10 1 2 Connecting a gate motor 10 1 3 Connecting an electric strike plate or lock 10 2 CONFIGURATION OF THE INTERCOM PANEL 10 2 1 Setting the volume of the intercom panel 10 2 2 Configuration of the RFID function 10 2 2 1 Programming or resetting the administrator badges 10 2 2 2 Add one or more user badges 11 2 2 3 Re...

Page 5: ...E MAIN OR ADDITIONAL INTERCOM PANEL 13 6 SMARTPHONE APPLICATION 13 6 1 Connecting a monitor to the WiFi network 13 F TECHNICAL AND LEGAL INFORMATION 16 1 GENERAL CHARACTERISTICS 16 2 WARRANTY 17 3 HELP AND ADVICE 17 4 PRODUCT RETURNS AFTER SALES SERVICE 17 5 EC DECLARATION OF CONFORMITY 17 ...

Page 6: ......

Page 7: ...to the device and void the warranty 2 MAINTENANCE AND CLEANING Before installing your intercom it is important to check the following points Do not install in cases of extreme humidity temperatures corrosion risk or dust Do not expose to direct sunlight rain or high humidity Do not plug the device into a multi socket plug adaptor or extension cord Be careful not to lose the administrator badge red...

Page 8: ...wires are needed for all functions bell video image intercom and strike plate and automatic opener controls For effective usage please carefully read this instruction manual 3 MONITOR 4 Plug in power supply 5 5 RFID badges 2 users grey 1 admin yellow 1 badge red 1 badge blue 1 7 monitor 2 Smart wall bracket 3 Intercom panel and protective shield 1 x 1 5 x 5 3 x 1 2 x 1 4 x 1 1 6 9 4 8 11 12 5 2 3 ...

Page 9: ...nnecting of the monitor 9 Connecting of the electric strike plate 10 Connecting of the dry contact gate automation 11 Loudspeaker volume setting located under the rubber button 12 RFID reset button under the rubber plug 5 WALL BRACKET The monitor is designed to be fixed to the wall A wall bracket and the necessary fasteners are included 6 MAINS ADAPTER A 230 Vac 50 Hz 15 Vdc 1A mains adapter for p...

Page 10: ... of your monitor 1 2 Wiring gate automation The intercom panel provides a dry contact connection without an electric current to be connected to the control button for your automated gate Connect it directly to the terminals identified on the description of the intercom panel Section 4 Intercom panel at the back of the board no polarity to follow The opening function can only be used if the respect...

Page 11: ...4 short beeps indicate activation of administration mode 2 Swipe 1 user badge grey that has been pre added to the system a short beep indicates that all the user badges have been cleared of any programming 2 2 5 Use of badges To open the electric strike plate quickly swipe your pre programmed grey user badge on the RFID reading field One short beep confirms the opening of the electric strike plate...

Page 12: ...itor Red Connection error Blue Connection OK or monitor not present Power supply indicator light Red Connection error Blue Power supply correctly connected Intercom panel connection indicator light Red Reverse polarity Blue Wiring OK Intercom panel connection indicator light Red intercom panel not connected wire unplugged or cut Blue connection OK This is completely normal if the monitor is used a...

Page 13: ...nature of the material the wall plugs provided are suitable for solid walls GND Connect the two wires from the monitor and if necessary connect the electric strike plate and the gate see Section 1 Wiring Check proper functioning video call etc GND Place a silicone seal between the shield and the wall to avoid the infiltration of water Do not use acetic acid based silicone vinegar odour It is not r...

Page 14: ...cted to the 2 4GHz WiFi network that will need to be connected to the monitor From the Thomson Smart Connect application click on to add a device Click on new device and then next Scan the QR Code on your videophone The QR code can be found in the WIFI menu of your videophone The application asks you to verify that your videophone is in pairing mode Your videophone is in pairing mode if the icon a...

Page 15: ...le phone emits a sound that allows it to connect to your videophone Place your phone next to the monitor microphone Choose the name of your videophone Your videophone is now connected to the WiFi network and your smartphone can receive calls The first time you view the video stream you will be asked to customise your password Note you will be asked for the password every time you wish to open your...

Page 16: ...e memory capacity 100 photos Sensor type CMOS Viewing angle 105 Average 400mA Dimensions 205 l x157 h x18 p mm Product connectivity WiFi 2 4 GHz IEEE 8111 b g n Dimensions 164 h x78 l x39 p mm Protection rating IP44 Temperature and humidity levels for use 10 C to 50 C 85 RH maximum Temperature and humidity levels for use 10 C to 50 C 85 RH maximum Screen Size 7 inches diagonally 17 78cm 16 9 Resol...

Page 17: ...nose the source of the problem as it will probably be the result of a setting that is incorrect or an installation that is not to specification If the problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may refuse to exchange your product Contact our customer service technicians on 0 35 min ...

Page 18: ...is a TECHNICOLOR S A brand used under licence by Avidsen 19 avenue Marcel Dassault 37200 Tours France ...

Reviews: