First issue 10 / 04
19
Factory Setting Procedure:
A. Press (Zoom -) key for over 5 seconds and release.
B. Press (Zoom+) key for over 5 seconds and release.
C. Press ”ok” key.
D. Factory setting OSD menu shows up.
The values showed up on the OSD menu are the factory default setting values. The factory default setting values differ from
each PDP panel module. The color temperature factory setting OSD menus are as the following:
*Note: GAIN Gamma and BIAS Gamma have no function
under RGB mode.
*Note: When adjusting the color temperature, please note
what is the input source and what input the PDP is, the
input source and the PDP input mode should be the same.
6. Put the color analyzer CA-100 in the center of the screen.
2.2 Adjusting procedure:
1. Receive Astro VG-828H RGB dark level center block signal (14 IRE), follow the ”Factory Setting Procedure” to go into
factory setting mode and you will see the 7180K color temperature setting OSD menu.
2. 7180K dark level center block adjustment procedure:
A. Press (Zoom -) or (Zoom+) key in remote control to select G-BIAS, and adjust Y=0.5 FL±0.1FL
B. Press (Zoom -) or (Zoom+) key in remote control to select R-BIAS, and adjust x=308±15FL
C. Press (Zoom -) or (Zoom+) key in remote control to select B-BIAS, and adjust y=298±15FL
D. Adjust R/G/B-BIAS, make sure the final value x=308±15FL, y=298±15FL, Y=0.5FL±0.1FL
3. 7180K bright level center block adjustment procedure:
(Please set Astro VG-828H RGB bright level center block signal to 60 IRE)
A. Press (Zoom -) or (Zoom+) key in remote control to select G-GAIN, and adjust Y=40±2FL
B. Press (Zoom -) or (Zoom+) key in remote control to select R-GAIN, and adjust x=308±15FL
C. Press (Zoom -) or (Zoom+) key in remote control to select B-GAIN, and adjust y=298±15F
D. Adjust R/G/B-GAIN, make sure the final value x=308±15FL, y=298±15FL, Y=40±2FL.
4. When you want to go ahead for next color temperature setting, double check the Gamma values, make sure GAIN Gamma
and BIAS Gamma values are correct, and then press the ”ok” key in remote control. For each color temperature setting,
please repeat the procedure (1)-(3). Only x and y value will change in different color temperature mode (in 8680K, x=288,
y=301; in 10180K, x=270, y=292) and Y values are all the same in each color temperature mode (dark level Y=0. 5, bright
level Y=40).
3.1 Color Temperature setting in AV Mode
1. Turn on Color Analyzer CA-100 and reset CA-100.
A. 7180K
R G B
-
C T
:
7
1
8
0
o
K
[x
:
3
0
8
y
:
2
9 8]
G A
I N
B
I A S
R
G
B
R
G
B
xx
xx
Xx
xx
xx
xx
xx
xx
B. 8680K
R G B
-
C T
:
8
6
8
0
o
K
[x
:
2
8
8
y
:
3
0 1]
R G B
-
C T : 1
[x
:
2
7
0
y
:
G A
I N
B
I A S
R
G
B
R
G A
I N
B
R
G
B
R
G
B
Xx
xx
Xx
xx
xx
xx
xx
xx
C. 10180K
0
1
8
0
o
K
:
2
9 2]
I A S
G
B
xx
xx
xx
x
xx
xx
xx
xx
(GAIN Gamma)
(BIAS Gamma)