3.0

BATTERY AND CHARGER USE

The tool is supplied with the batteries completely discharged; before use, fully charge the batteries using the charger supplied.

This tool is supplied with a battery charger CFC 120Y and adapter CBA96-144, 

which is required for 9.6V batteries (CB9620H). With the adapter removed, the 

same charger may be used with the 14.4 V Batteries common to other Thomas & 
Betts battery operated tools.

For optimum battery life, please follow the rules:

 Use the battery until the automatic residual energy display still has 1-2 red 

LEDs showing: this means the battery is almost completely discharged 

and no loss in the life of the battery has been produced. This is particularly 

important when charging a new battery the first 2-3 times in order to 

maximize the available energy level.

 Allow the battery to cool down to ambient temperature prior to recharging.

 Rest the battery charger for at least 15 minutes between charges.

BATTERY STATUS 

(Refer to Fig. 4)

 

3.1               

• After releasing the operating button, the residual 

battery capacity is automatically displayed for 5 
seconds on the indicator (11). 

  The number of LEDs illuminated indicates the residual 

capacity:

6 LEDs illuminated:  Fully Charged
3 LEDs illuminated:  50% capacity
1 LED illuminated: Minimum charge

To replace the battery, press the two red buttons at the 
same time and slide the battery forward. 

GENERAL BATTERY & CHARGER USE

3.2               

CHARGER SPECIFICATIONS

Input Voltage

100-120V~50-60Hz

Output Voltage

7.2-14.4V

Charging Current

2.4A

Trickle Charge

60mA

Weight

1.1 lbs.

Fig.  5

Back of Tool

  

OPERATING LOCATIONS 

The chargers are designed for use in dry areas. All ventilation slots must be kept unobstructed. If 

possible, keep away from heat sources and out of direct sunlight as ambient temperatures in excess of 35°C may increase 
charging times considerably.

 

AC SUPPLY CONNECTION 

Before connecting the charger, check that the AC-supply voltage and frequency are the same 

as those indicated on the charger. The charger is ready for operation when the power cord is connected to the live AC 
supply.

  

PUTTING INTO SERVICE AND OPERATION 

Left-hand, red LED 

If the charger is connected to the AC supply and the left 

hand LED goes red, the charger is OK.

 If the left-hand LED is red and flashing the charger has a fault  

Further charging is 

not possible.

  

CHARGING PROCEDURE  (

See table on the right.) 

  The battery charger checks the voltage, temperature,  

short-circuit and polarity of the batteries before charging.  
The safety elements (bi-metal strip or NTC resistor) are 
checked via the temperature contact. 

 

If the safety elements are OK, the right-hand LED goes 

green and the charging procedure commences 

 

  Charging state detection is a special feature of this charging 

method. If the right-hand led remains switched off, the 
internal circuit of the battery either is open or there is a 
condition of polarity inversion. 

(Continued on next page)

BATTERY CHARGER OPERATION

3.3               

LED, left-hand, red

LED, right-hand, multi-coloured

Red LED on 

Red LED flashing 

Red LED on

Red/green LED flashing 

Green LED flashing 

Green LED on

Red LED flashing

Charger is connected to the supply

and ready for operation 

Charger is defective

Charging started

Battery is full charged

The power supply is less than 10,5 V

(only for CFC12-24IC)

Battery is defective

Battery is too hot or too cold

100%

BATTERY

ADAPTER

Summary of Contents for BPI42CR

Page 1: ...servicing this tool BPI42CR and BPI42300CR Battery Operated Hydraulic Crimping Tool Operating Instruction Manual 1 0 General Characteristics 2 2 0 Instructions for Use 3 3 0 Battery and Charger Use 4...

Page 2: ...essure relief safety valve Directive 2006 42 EC annexe 1 point 1 7 4 2 letter u The weighted continuous acoustic pressure level equivalent A at the work place LPA is equal to 66 8 dB A The maximum val...

Page 3: ...ress the operating button 3 to activate the motor pump and advance the lower die To halt the advancement release the operating button 3 and the motor will stop Make sure the dies are exactly positione...

Page 4: ...Tool OPERATING LOCATIONS The chargers are designed for use in dry areas All ventilation slots must be kept unobstructed If possible keep away from heat sources and out of direct sunlight as ambient te...

Page 5: ...rom the charger so that it can return to its proper temperature range Continuous red right hand LED The battery is defective CHARGING TIMES The following table lists the various charging times the cha...

Page 6: ...e parts always specify the following Code number of item Name of item Type of tool Tool serial number Warranty is void if replaced parts are not Thomas Betts original replacement parts For parts or se...

Page 7: ...Betts warrants that this product will be free from defects in materials and workmanship for the period stated on the enclosed warranty card Upon prompt notification of any warranted defect Thomas Bett...

Page 8: ...port 1 6000565 300 27 Cap 1 Code N ITEMS DESCRIPTION QTY Main 1st Sub 2nd Sub 6641027 300 30 Washer 1 6000567 300 31 Lockout 1 6000603 300 45 Pressure Release Lever 1 6000570 300 57 Spring 1 6740100 3...

Reviews: