Operating

NOTICE!
Possible damages caused by unsuitable fog fluid
Fog liquids not approved by the manufacturer may permanently damage the

unit.
Only use the fog fluids listed on 

www.thomann.de

 and follow their instructions for

use.

First, make sure the unit is switched off.
Open the screw-cap of the liquid container and fill in the fog fluid. Make sure that no fog fluid

is spilled or gets into the device. The easiest way is using a funnel.
Screw the cap firmly back on.

Filling the unit

Operating

 

 

fog machine

28

Summary of Contents for STAIRVILLE M-Fog 3000 Pro

Page 1: ...M Fog 3000 Pro fog machine user manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 05 10 2021 ID 526628...

Page 3: ...d signal words 9 2 Safety instructions 12 3 Features 17 4 Installation 18 5 Starting up 19 6 Connections and controls 21 7 Operating 28 7 1 Basic settings 30 7 2 Manual control 33 7 3 Device informati...

Page 4: ...9 Troubleshooting 41 10 Cleaning 43 11 Protecting the environment 45 Table of contents fog machine 4...

Page 5: ...t is available to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous d...

Page 6: ...d search Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Per...

Page 7: ...The letterings for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and ita...

Page 8: ...o Automatic operation is started 3 Switch off the device References to other locations in this manual are identified by an arrow and the specified page number In the electronic version of the manual y...

Page 9: ...avoided WARNING This combination of symbol and signal word indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided CAUTION This combination of symbol...

Page 10: ...Warning signs Type of danger Warning high voltage Warning flammable substances Warning hot surface Warning slip hazard Warning harmful or irritating substances General information fog machine 10...

Page 11: ...Warning signs Type of danger Warning danger zone General information M Fog 3000 Pro 11...

Page 12: ...ent physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is respo...

Page 13: ...d electrician WARNING Risk of burns from flammable liquids The use of flammable liquids in this device may cause severe burns and damage to property Always use approved fog fluids Never fill flammable...

Page 14: ...mmediately Keep fog fluid in a safe place If the fog fluid comes into contact with eyes rinse thor oughly with water CAUTION Possible respiratory problems The device can be operated safely only with t...

Page 15: ...smoke nicotine fog etc the unit should be maintained by qualified service personnel at regular intervals to prevent overheating and other malfunction NOTICE Power supply Before connecting the device...

Page 16: ...ng instructions n Never leave the device running without supervision n The device is not suitable for use in private households or as a child s toy n Place the device on a stable fire proof basis that...

Page 17: ...ontrol via DMX 1 channel buttons and display on the unit or the supplied remote con trol n Suitable for mobile use n Large liquid container for the fog liquid n Carrying handles for easy handling n Pr...

Page 18: ...vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Place the unit on a flat surface T...

Page 19: ...ons Take care when running the cables to prevent tripping hazards NOTICE Possible data transmission errors For error free operation make use of dedicated DMX cables and do not use ordi nary microphone...

Page 20: ...ther DMX device Connect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is ter...

Page 21: ...6 Connections and controls 4 5 PUSH PUSH Connections and controls M Fog 3000 Pro 21...

Page 22: ...er with screw cap 4 Carrying handle 5 Display with function buttons MENU Activates the main menu and toggles between menu items UP Increases the displayed value by one DOWN Decreases the displayed val...

Page 23: ...tinuous mode Press ENTER to start fog output press ENTER again to stop fog output Timing mode Press ENTER to start fog output time controlled press ENTER again to stop fog output 6 ON OFF Main switch...

Page 24: ...10 DMX Output DMX output 3 pin 11 DMX Input DMX input 5 pin 12 DMX Output DMX output 5 pin 13 Remote Control Connection for the remote control Connections and controls fog machine 24...

Page 25: ...TIMER ON OFF CONTINUOUS MANUAL OUTPUT INTERVAL DURATION 0 6 2 7 3 1 4 5 Remote control Connections and controls M Fog 3000 Pro 25...

Page 26: ...s that the unit has reached the operating temperature necessary to produce fog 18 MANUAL Push this button for maximum fog output regardless of other settings 19 The control LED indicates that the devi...

Page 27: ...2 TIMER ON OFF With this button you can turn the Timer function on or off In this operating mode the amount of fog set with the rotary control OUTPUT is emitted at the interval that you have set with...

Page 28: ...he fog fluids listed on www thomann de and follow their instructions for use First make sure the unit is switched off Open the screw cap of the liquid container and fill in the fog fluid Make sure tha...

Page 29: ...dry An electronic protection circuit switches off the pump when the liquid container and hose are empty If the protection circuit is triggered the display flashes and shows WARNING Fluid ERROR 3 Refil...

Page 30: ...lay shows DMX Addr 3 Press UP or DOWN to set the DMX address in the range between 1 and 512 4 Press ENTER to confirm the selection Please note that manual control is deactivated when operating with DM...

Page 31: ...n 0 and 100 4 Press ENTER to confirm the selection 1 Press MENU repeatedly until the display shows SETUP and confirm with ENTER 2 Press MENU repeatedly until the display shows Interval 3 Press UP or D...

Page 32: ...UP and confirm with ENTER 2 Press MENU repeatedly until the display shows Duration 3 Press UP or DOWN to set the duration of a fog blast in the range between 1 and 999 4 Press ENTER to confirm the sel...

Page 33: ...The maximum amount of fog is emitted regardless of the other settings 3 Release ENTER to stop fog output Please note that manual control is deactivated when operating with DMX After removing the DMX c...

Page 34: ...t is emitted con tinuously 1 Press MENU repeatedly until the display shows CONTINUOUS 2 Press ENTER to turn the continuous mode The set amount of fog is continuously emitted 3 Press ENTER again to tur...

Page 35: ...nd for the duration that you have set under Duration 1 Press MENU repeatedly until the display shows TIMING 2 Press ENTER to turn on the time controlled operation The set amount of fog is continuously...

Page 36: ...MENU repeatedly until the display shows SETUP and confirm with ENTER 2 Press MENU repeatedly until the display shows Info and confirm with ENTER The display shows the current version number of the de...

Page 37: ...setting 1 Press MENU repeatedly until the display shows SETUP and confirm with ENTER 2 Press MENU repeatedly until the display shows Rest 3 Press ENTER to reset the device to factory default setting...

Page 38: ...25 Post heating time approx 30 s Control DMX buttons and display on the unit remote control Input connections Voltage supply lockable input socket Power Twist DMX control XLR chassis plug 3 pin XLR c...

Page 39: ...230 V 50 Hz Fuse 5 mm 20 mm 15 A 250 V fast acting Protection class IP20 Mounting options Upright Dimensions W H D 368 mm 288 mm 615 mm Weight 17 5 kg Ambient conditions Temperature range 0 C 40 C rel...

Page 40: ...last direction Horizontal Timer remote control yes On off remote control yes Radio remote control No Light effect No Battery operation No Hanging bracket No Further information Technical specification...

Page 41: ...9 Troubleshooting In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting M Fog 3000 Pro 41...

Page 42: ...igh voltage cables that may cause damage or interference to a DMX interface circuit No fog output 1 Check the fluid level in the fog container 2 Switch the device off and check the hose that leads int...

Page 43: ...onger period of time 1 Make sure that the device is turned off disconnected from the mains and completely cooled down 2 Position the unit in a well ventilated place 3 Insert the suction hose of the fo...

Page 44: ...cleaning is completed The fan grids of the device must be cleaned of any contamination such as dust etc on a reg ular basis Before cleaning switch off the device and disconnect mains operated devices...

Page 45: ...e notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal ho...

Page 46: ...Notes fog machine 46...