Press
[MENU]
repeatedly until the display shows
‘Firmware Version’
. Press
[ENTER]
.
The display shows the device’s firmware version.
Press
[MENU]
to close the display of the firmware version.
Press
[MENU]
repeatedly until the display shows
‘Default’
. Use and to now select
between
‘no’
(no action) and
‘Yes’
(reset all values to factory defaults).
If the display shows the required value, press
[ENTER]
and then
[MENU]
. To return to
the main menu without making changes, wait around 30 seconds.
Press
[MENU]
repeatedly until the display shows
‘Reset’
. Press
[ENTER]
. The device is
reset to its default settings.
7.3 Calibration
The starting position of all mechanically powered elements can be adjusted in fine
increments. To open the calibration menu, press
[MENU]
and then press
[ENTER]
for
three seconds. Then using and , select the element you wish to calibrate. Press
[ENTER]
. Use and to adjust the selected element. Once the display shows the
required value, press
[ENTER]
.
The following table shows the possible settings.
Display
Element
Value range
from
to
‘Pan Offset’
Rotation (pan)
-127
127
‘Tilt Offset’
Inclination (tilt)
-127
127
‘Dimmer Offset’
Mechanical dimmer
0
255
‘Color Offset’
Colour wheel
-127
127
‘Gobo1 Offset’
Gobo wheel 1
-127
127
‘Gobo2 Offset’
Gobo wheel 2
-127
127
‘RGobo Offset’
Rotation of the gobos in gobo wheel 2
-127
127
‘Prism1 Offset’
Prism wheel 1
0
255
‘RPrism1 Offset’
Rotation of the prisms in prism wheel 1
-127
127
‘Prism2 Offset’
Prism wheel 2
0
255
‘RPrism2 Offset’
Rotation of the prisms in prism wheel 2
-127
127
‘Frost Offset’
Frost filter
0
255
‘Zoom Offset’
Mechanical zoom
0
255
‘Focus Offset’
Mechanical focus
0
255
Firmware version
Loading default settings
System reset
Operating
moving head
18