Cleaning

NOTICE!
Possible damages caused by unsuitable cleaning agents
Cleaners not approved by the manufacturer may permanently damage the unit.
Only use the fog machine cleaners listed on 

www.thomann.de

 and follow their

instructions for use.

Clean the appliance after every 30 operating hours, or if it was not in use for a longer period of

time.
1.

Make sure that the device is turned off, disconnected from the mains and completely

cooled down.

2.

Position the unit in a well ventilated place.

3.

Insert the suction hose of the fog machine into the bottle with the fog machine cleaner.

4.

Connect the device to the mains power grid and turn it on with the main switch.

5.

Wait until the unit has reached the required operating temperature.

Procedure

Cleaning

 

 

fog machine

34

Summary of Contents for fun generation LED-Fogger 500 CO2 RGB

Page 1: ...LED Fogger 500 CO2 RGB fog machine user manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 17 10 2019 ID 455672...

Page 3: ...nventions 6 1 3 Symbols and signal words 6 2 Safety instructions 10 3 Features 20 4 Installation 22 5 Connections and controls 23 6 Operating 27 7 Technical specifications 30 8 Troubleshooting 33 9 Cl...

Page 4: ...it is available to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous...

Page 5: ...rch Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal...

Page 6: ...for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button 1 3 Symbols and signal words In this section you will find an overview of the meaning of symb...

Page 7: ...that can result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a pos sible dangerous situation that can result in minor injury if it is no...

Page 8: ...ing signs Type of danger Warning flammable substances Warning hot surface Warning dangerous optical radiation Warning slip hazard Warning harmful or irritating substances General information fog machi...

Page 9: ...Warning signs Type of danger Warning danger zone General information LED Fogger 500 CO2 RGB 9...

Page 10: ...be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical...

Page 11: ...om the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where hi...

Page 12: ...plug Failure to do so could result in electric shock death or fire If in doubt seek advice from a regis tered electrician WARNING Risk of burns from flammable liquids The use of flammable liquids in t...

Page 13: ...nozzle during and shortly after operation It becomes very hot and may cause burns even several hours after switching off the device WARNING Risk of slipping caused by condensate Fog machines can produ...

Page 14: ...advice immediately Keep fog fluid in a safe place If the fog fluid comes into contact with eyes rinse thoroughly with water WARNING Eye damage caused by high light intensity Never look directly into t...

Page 15: ...on approved fluids shall be excluded Do not create fog in closed or poorly ventilated areas Do not expose persons with health problems such as allergic respiratory condi tions asthma to artificial fog...

Page 16: ...r the batteries Ensure that proper polarity is observed when inserting batteries NOTICE Possible damage by leaking batteries Leaking batteries can cause permanent damage to the device Take batteries o...

Page 17: ...tions of this user manual Avoid heavy temperature fluctua tions and do not switch the device on immediately after it was exposed to tem perature fluctuations for example after transport at low outside...

Page 18: ...gned for use in professional event technology and works reliably when used properly Observe the following information n Follow all warnings in these operating instructions n Never leave the device run...

Page 19: ...rient themselves safely n The haze or mist generated by the device may trigger smoke alarms NOTICE Possible damage due to installation of a wrong fuse The use of different types of fuses can cause ser...

Page 20: ...tical fog column of approx 3 m height n Coloured fog effects by built in RGB LEDs n Manual control via wired remote control with direct control of 8 colour combinations n Flash button on the device fo...

Page 21: ...es over their lifetime This effect increases with higher operating temperature You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowe...

Page 22: ...isture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively The device is designed for horizontal or vertical insta...

Page 23: ...5 Connections and controls Rear panel Connections and controls LED Fogger 500 CO2 RGB 23...

Page 24: ...f 4 STROBE Turns the Stroboscope effect on and off 5 HEATING READY Indicator LED for heating up and operating status 6 Fog fluid container with screw cap 7 LED effect ring and fog nozzle for fog outpu...

Page 25: ...Wired remote control Connections and controls LED Fogger 500 CO2 RGB 25...

Page 26: ...use ON is lit The trigger button on the remote is activated 11 1 8 Activates a colour combination and simultaneously triggers a fog output 1 Red 5 Purple 2 Green 6 Cobalt blue 3 Blue 7 White 4 Yellow...

Page 27: ...omann de and follow their instructions for use First make sure the unit is disconnected from the mains Open the screw cap of the liquid container and fill in the fog fluid Make sure that no fog fluid...

Page 28: ...erheating and permanent damage of the pump When operating always ensure that there is sufficient fog fluid in the liquid con tainer to avoid no load running Connect the remote control to the connector...

Page 29: ...again STROBE on the rear panel of the unit Turn off the power using the main switch Transport the device only when it is completely cooled down To avoid leaking fog fluid during transport you should t...

Page 30: ...40 ml min For burst duration max approx 6 s Charging time between fog bursts approx 40 s Fog burst reach 3 m Input connections Voltage supply IEC chassis plug C14 Output connections Wired remote contr...

Page 31: ...5 mm 20 mm 5 A 250 V fast acting Protection class IP20 Dimensions W H D 290 mm 250 mm 150 mm Weight 3 3 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 50 non condensing Technical...

Page 32: ...rection Vertical Timer remote control included No On off remote control included Yes Radio remote control included No Light effect included Yes Hanging bracket No Further information Technical specifi...

Page 33: ...ction and main fuse 2 Check that the fog fluid and or water tank is sufficiently filled 3 Check the hose connections of the fog fluid and the water tank No response to the wired remote control Check i...

Page 34: ...ating hours or if it was not in use for a longer period of time 1 Make sure that the device is turned off disconnected from the mains and completely cooled down 2 Position the unit in a well ventilate...

Page 35: ...econds This will rinse the lines The cleaning is completed The fan grids of the device must be cleaned of any contamination such as dust etc on a reg ular basis Before cleaning switch off the device a...

Page 36: ...the notes and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal...

Page 37: ...Notes LED Fogger 500 CO2 RGB 37...

Page 38: ...Notes fog machine 38...

Page 39: ......

Page 40: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...