8. Appendix
8-8
CSKR
8-7
Suction
We conducted a dust generation test, and this model has achieved the classification of clean-room
level of ISO14644-1 class 4 by the internal suction mechanism.
Table 5 shows the suction volume during a dust generation test for your reference.
Table 5 Suction volume during a dust generation test
Model number
Suction volume (L/min)
CSKR20
5~10
CSKR26
5~15
CSKR33
30~40
CSKR46
40~50
Note 1) The suction volume during a dust generation test is the same as that in accordance with
the class 4 criteria when operating at the maximum travel speed (the rotation speed of the
ball screw: 6000 min
-1
).
Note 2) The suction volume does not include the influence of the pipe resistance. Note that the
pipe length or pipe diameter may incur the pipe resistance that will decrease the flow rate.
z
Suction joint
The suction joint has adopted the one-touch system, which makes it easier to connect using a
off-the-shelf air tube.
Table 6 Suction joint
Model number
Connection screw size
Applicable tube outer
diameter (mm)
CSKR20
R1/8
ø6
CSKR26
R1/8
ø6
CSKR33
R1/8
ø8
CSKR46
R1/4
ø10
8. Appendix
www.thk.ru
тел. +7(499) 703-39-86