Page 18
TLX1280 Matrix Switch Product Manual
thinklogical
Rev. B, March 2019
Section 3: Set-Up and Installation
Order of Installation Events
1. Prepare a suitable area to permanently house the TLX1280 in a full-size rack and
complete any pre-installation requirements, including redundant AC sources.
2. Check the contents of each container in your shipment
(
see below
)
.
3. Ensure all TLX1280 components are fully seated
(pg. 19, Steps 1 & 2)
.
4. Unpack the Chassis
(pg. 19, Steps 3 & 4)
.
5. Install the Chassis into its permanent mounting rack
(pg. 19, Step 5)
.
6. Unpack and install the modules, spares and options
(pg. 19, Steps 6 & 7)
.
7. Connect the TLX1280 to the Ethernet and set the static IP address via the DIP
switch located on the Interconnect Card
(pg. 21)
.
8. Connect peripherals to Receivers, then Receivers to the TLX1280
(pg. 24)
.
9. Connect sources and peripherals to Transmitters, then Transmitters to the
TLX1280
(pg. 24)
.
10. Connect the TLX1280 to an External Control CPU
(pg. 25)
.
AC Source Requirements
Thinklogical
®
strongly recommends that each AC inlet be supplied from a separate single-phase
200-240VAC, 50-60 Hz circuit capable of delivering 20A.
Contents
When you receive your Thinklogical
®
TLX1280 Matrix Switch, you should find the following items
in the quantities specified in your order:
•
TLX1280 Chassis
(
with Fan Tray and Interconnect Card installed
)
➢
Top-mount lifting fixtures (2) and front-mount lifting fixtures (4)
•
Shipped Separate:
1 or 2 Controller Card(s), 8 Switch Cards, up to 40
Input/Output Cards, Filler Cards as
needed
,
6 Power Modules and Power Cords
–
PWR-59-R
(International connections may differ)
➢
Product Manual CD
➢
Product Quick Start Guide
•
Options and Spares
:
➢
Back-Up Controller Card
➢
Spare Fan Tray
➢
Spare Power Supply Modules
➢
32-Port Data Input/Output Cards (1-40)
➢
Faceplate Filler Cards ENC-1825
➢
Fiber Management Racks
➢
Custom Fiber-Optic Cable Bundles (available)
The TLX1280 Matrix Switch ships configured to customer specifications. Controller and I/O Cards ship
separately from the Chassis in customer-specified quantities. Faceplate Filler Cards (ENC-1825) are
provided as needed to fill all empty card slots.