How it works

Tips

ThinkEco Web App

• Displays real-time and historical energy consumption data. 
• Allows you to schedule your window A/C on or off or change the 

SET TO

 

temperature from a computer or mobile device. 

(This is equivalent to programming a 

household thermostat to turn off and on at certain times of the day.)

modlet

• Controls the flow of electricity to your window A/C unit.
• Monitors real-time energy consumption of your window A/C unit and communi-

cates this data to your computer via the USB receiver. 

smartAC thermostat

 

• Measures the current temperature inside the room and communicates the 

temperature to the modlet.

• Allows you to program a 

SET TO

 temperature that you would like the window 

A/C unit to maintain. 

(When the temperature in the room is greater (warmer) than the 

SET TO temperature and your A/C is scheduled on, the modlet turns your window A/C on. If 
the temperature is less (colder) than the SET TO temperature, the modlet turns your window 
A/C off. )

1.  Set your window A/C unit to high and cold.

 

When you first set up your modlet, use the controls on your A/C unit to set 
it to a cold temperature and high fan speed. This will help your room cool 
down and reach your target temperature faster. 

2.  Use the wireless remote instead of your A/C controls.

 

After the modlet is set up, use the wireless thermostat to change the SET TO 
temperature. The thermostat communicates both the current and SET TO 
temperature directly to the modlet so it can control your window A/C unit. 

3.

  

Turn on your computer and plug in your USB at least  
once a week. 

Energy consumption and temperature data is only transmitted from the modlet 
to your computer when your computer is on and the USB receiver is plugged 
in. The modlet can store this data for up to 10 days, but your computer must 
be on to monitor or control your A/C from a smart phone or computer outside 
your home or to participate in the demand response events.

4.

  

Keep your thermostat in the same room as your A/C. 

 

Each thermostat is programmed to work with one modlet and window A/C.  
If you have multiple A/Cs and modlets in your apartment, make sure that you 
leave the thermostat in the same room as the A/C that it controls to ensure 
accurate temperature readings. 

5.

  

Keep the thermostat near the center of the room. 

Since the thermostat has an internal thermometer to measure the room 
temperature, keep the thermostat toward the middle of the room for an 
accurate reading (i.e. – not right next to the window A/C or in a hot sunny 
window).

To maximize the performance of your modlet A/C system, use the 
following tips.

The modlet smartAC kit converts any window air-conditioner into an 
Internet-enabled device with smart thermostat control and scheduling 
capabilities.

Summary of Contents for modlet smartAC

Page 1: ...A Con Edison program in partnership with ThinkEco User Guide smartAC...

Page 2: ...en on the Con Edison distribution system By participating in this program you will gain the ability to see how much energy your window A C units are using as well as gain remote control of your window...

Page 3: ...rtAC thermostat modlet USB gateway smartAC thermostat Red LED light 3 pin wall outlet modlet button Power LCD Display screen Toggle up Toggle down Menu Features LED light status Light not on Solid red...

Page 4: ...ur computer that you want to monitor Click Search on the Install er first then plug the modlet into the outlet The spinning LED light will stop when your modlet joins the network Plug your A C back in...

Page 5: ...and select Open Modlet Manager For Mac go to Applications ThinkEco and then Modlet Manager to control when your devices are on and off Please note during the initial baseline period scheduling is not...

Page 6: ...controls After the modlet is set up use the wireless thermostat to change the SET TO temperature The thermostat communicates both the current and SET TO temperature directly to the modlet so it can c...

Page 7: ...our window A C to be on the thermostat is activated and works with the modlet to maintain the target temperature in the room Please note this feature is only available after the initial baseline perio...

Page 8: ...or year Baseline period is the first month after you set up your modlet It monitors normal energy consump tion before schedules are implemented Savings calculated based on difference between energy c...

Page 9: ...room temperature Turn your devices on or off remotely Click to turn on or off the demand response setting Review your schedules for today See the current room temperature and Con Edison Alerts Review...

Page 10: ...IEE 802 15 4 wireless communication Power source 2 AAA Batteries Important Safety Information Use indoors in a dry location Do not use this product in connection with critical care equipment i e life...

Page 11: ...e and this warranty does not cover any damages caused by or to any third party device ThinkEco will make the final determination as to the existence and cause of any alleged defect No warranty is made...

Page 12: ...148 Madison Avenue 8th Floor New York NY 10016 www thinkecoinc com Assembled in the USA...

Reviews: