Protocol Faults
62
Appendix A: Error Messages
FAULT_NO_TAGS_FOUND – (400h)
Cause
A command was received (such as like read, write, or lock) but the operation failed. There
are many reasons that can cause this error to occur.
Here is a list of possible reasons that could be causing this error:
No tag in the RF field
Read/write power too low
Antenna not connected
Tag is weak or dead
Solution
Make sure there is a good tag in the field and all parameters are set up correctly. The best
way to check this is to try few tags of the same type to rule out a weak tag. If none
passed, then it could be SW configuration such as protocol value, antenna, and so forth,
or a placement configuration like a tag location.
FAULT_NO_PROTOCOL_DEFINED – 401h
Cause
A command was received to perform a protocol command but no protocol was initially
set. The reader powers up with no protocols set.
Solution
A protocol must be set before the reader can begin RF operations.
FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
Cause
The protocol value was set to a protocol that is not supported with the current version of
SW.
Summary of Contents for Mercury6e M6e-30dBm
Page 1: ...M6e 31 5dBm Hardware Guide For M6e Firmware Ver 1 7 and later ...
Page 4: ...4 ...
Page 14: ...14 Mercury6e Introduction ...
Page 26: ...Assembly Information 26 Hardware Overview M6e Mechanical Drawing ...
Page 52: ...Save and Restore Configuration 52 Functionality of the Mercury6e ...
Page 78: ...Demo Application 78 Appendix B Getting Started Devkit ...