3.3 Electrical Installation
3.3.1 Wiring
In order to build a low-noise (i.e. EMC-compliant) measurement system, the data and
measuring lines must be shielded. Thorough earthing of the shielding is to be ensured.
Depending on local conditions, a distinction is to be made between:
•
Metal housing
:
Shields of the lines contact directly to EMC cable glands.
•
Plastic housing or no housing
:
Produce shield connections via suitable rails or metallic installation plate with
appropriate clamps/adhesive bands (see
Figure 2
). The clamps must ensure large-
area contact to the cable shield.
Figure 3: Example of the earthing of the device