3  Mode of Operation 

Precipitations in the form of drizzle, rain, snow, or hail are acquired by a light barrier system, 
and trigger a switch signal. 

An integrated event filter suppresses the triggering of the switch signal with accidental single 
events, such as leafs, bird droppings, insects etc.  

 

Output 1: (relay)

 

The relay signalizes the start and end of a precipitation period.  

Start of Precipitation: 
The recorded events (raindrops, hailstones, etc.) are compared with the set threshold value 
(number of events) within a time frame of 50sec. On reaching the threshold value the relay is 
switched.  

The time frame is to be considered as gliding, i.e. you always look into the past. When after 
the start of a precipitation event the number of events for the threshold value is reached 
within a short time (< 50sec.) the relay is switched. This might occur even within a clearly 
shorter time than 50sec. 

End of Precipitation: 
The reset of the relay, i.e. the end of the precipitation period, occurs when no more 
raindrops, hail stones, etc. are detected after a defined delay. 

 

Output 2: (optocoupler) 

The optocoupler signalizes each event, as soon as a particle has been acquired by the light 
barrier. The acquisition or signalizing is carried out without filtering and without delay. 

 

Heating 

 

The instrument is equipped with a heating system for extreme weather condition. This avoids 
ice and snow forming on the housing surface. In addition, the surface retains a temperature 
of >0° by means of a regulated heating. 

Heating mode for: 

Different modes of heating are possible: 

Heating mode A  
The heating is always active, the control temperature is at approx. 8°C  

Heating mode B  
The heating is active, when the precipitation monitor detected precipitation, and the ambient 
temperature is at < 8°C.  

Heating mode C  
The heating can be switched ON or OFF externally, control temperature is at approx. 8°C  

Heating mode D  
The heating can be switched ON or OFF externally, and is active when the precipitation 
monitor detected precipitation, and the ambient temperature is at < 8°C.  

 

 

 

Summary of Contents for 5.4103.1 Series

Page 1: ...Precipitation Monitor Instruction for use 5 4103 1x xxx 5 4103 31 000 Dok No 021197 07 19 T H E W O R L D O F W E A T H E R D A T A...

Page 2: ...e product is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by...

Page 3: ...itation Sensor with Cable Gland 7 4 2 1 Connector for Precipitation Monitor with factory connected Cable 7 4 2 2 Connector for Precipitation Monitor without factory connected Cable 8 4 2 3 Electrical...

Page 4: ...for external ON OFF heating control 5 4103 11 000 Precipitation status Relay Optocouplers 12 28V AC DC yes mode A Terminal strip and cable gland 5 4103 31 000 Precipitation status Relay Optocouplers...

Page 5: ...occur even within a clearly shorter time than 50sec End of Precipitation The reset of the relay i e the end of the precipitation period occurs when no more raindrops hail stones etc are detected afte...

Page 6: ...ntact W R closed Precipitation yes is signalized with missing or interrupted operating voltage sensor off thus device protection is existing even in this status 3 2 Definition to the Precipitation Eve...

Page 7: ...nt while operating is not exposed to strong vibrations or shocks The pictured tube is not included in delivery 5 4103 11 000 The operating position of the precipitation monitor is horizontal The holdi...

Page 8: ...the upper part again and screw it evenly and tightly to the bottom Attetion Make sure that the contact pins are not deformed when putting on the cover The fixing screws for the cover must be srewed d...

Page 9: ...Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 9 von 20 4 2 4 Connection Diagramm Note The cable shield must only be placed on the side of th...

Page 10: ...551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 10 von 20 1 2 3 4 5 6 7 Article No 5 4103 10 700 Polbild mit Sicht auf L tanschluss des Gegenstecker Article No 5 4103 10 1...

Page 11: ...elay output is undefined after switching on the operating voltage and shows no precipitation 6 Maintenance The device is maintenance free Cleaning The pollution and the pollution level is dependent on...

Page 12: ...due to special ambient conditions this can be done by means of switches DIP1 and DIP2 DIP1 Switch off delay for the end of precipitation period DIP2 Drop event filter for the start of precipitation p...

Page 13: ...F ON ON 12 ON OFF ON ON 325 ON OFF ON ON 13 OFF ON ON ON 350 OFF ON ON ON 14 ON ON ON ON 375 ON ON ON ON 15 Grey marked squares factory settings DIP switch adjustment OFF OFF OFF OFF not defined 7 3 D...

Page 14: ...pitation yes relay contract W R closed Precipitation no relay contract W A closed Power failure Sensor off relay contract W R closed Switch on condition 1 15 incidences within 50sec settable Switch of...

Page 15: ...fo thiesclima com www thiesclima com Seite 15 von 20 Heating Control temperature Hysteresis Power Two level controller approx 8 C 0 1K Max 0 5A 12V max 1A 25V Ambient temperature 30 60 C Protection IP...

Page 16: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 16 von 20 5 4103 10 700 5 4103 11 000...

Page 17: ...Accessories Optional Power Supply Unit 9 3388 00 002 The power supply unit serves for the current supply of the precipitation monitor order no 5 4103 10 000 It supplies the necessary operation voltage...

Page 18: ...to the making available on the market of electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 Mar...

Page 19: ...Adolf Thies GmbH Co KG Hauptstra e 76 37083 G ttingen Germany 021197 07 19 Tel 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Seite 19 von 20...

Page 20: ...001 65 info thiesclima com www thiesclima com Seite 20 von 20 Sprechen Sie mit uns ber Ihre Systemanforderungen Wir beraten Sie gern ADOLF THIES GMBH CO KG Meteorologie und Umweltmesstechnik Hauptstra...

Reviews: