5.1 Mechanical Mounting
The wind transmitter must be mounted on an instrument carrier, which is suited for the measure-
ment. For dimensions of wind direction transmitter please refer to chapter 8.
Tools:
Hexagon socket wrench SW3
(Allen
key)
Procedure:
1. Push cable/ plug connector of the wind
transmitter through the borehole of the
mast, tube, arm etc.
2. Put wind transmitter on mast, tube, arm
etc.
3. Safeguard the wind transmitter by two
M6-Allen head screws
Remark:
Suitable instrument carriers are masts, tubes, traverses, arms, adapters, adapters of POM for iso-
lated mounting, which correspond to the mounting dimensions of the wind transmitter, and to the
static requirements.
The inner diameter of the instrument carrier should be
≥
20 mm based on plug- and cable feed-
through.
5.2 Electrical Mounting
5.2.1 Cable
Solder a shielded cable with diameter 7-8 mm and a core cross-section of 0.5...0.75 mm² to the
enclosed coupling socket.
•
The number of necessary wires is given in the connection diagram (chapter 5.3).
5.2.1.1 Cable
Recommendation
No. of wires/ diameter / type / cable diameter
CABLE 4X0.5mm² LI9YC11Y BLACK, UV- resistant, Ø 6 mm
CABLE 8x0.5mm² LIYCY BLACK, UV- resistant, Ø 7.6 mm
5.2.2 Cable
Shield
The connection of the cable shield between sensor and data acquisition device should be selected
in way, that in case of over-voltages no equalizing currents will flow that might destroy the elec-
tronic components.
The connection of the cable shield should depend on the selected isolated, or respectively, non-
isolated mounting of the sensors.