7 Settings
An
8-fold DIP switch
(settings) S1…S8
is located on the rear panel of the device (refer to
Figure 2: Rear panel 4.3251.0x.001
) for basic setting of different parameters.
Note:
A restart, which is effected via actuation of the key „Info Reset“ or via interruption of the
power supply, must be carried out upon change of switch setting.
COM4
Figure 5: DIP switch
7.1 Setting Operating Mode
* = Delivery status
Attention:
The setting is only accepted after a restart!
Operating mode
S1
S2
WD instantaneous
on
on
WD delayed
off
on
WD inst. & variation
on
off
WD delayed & variation *
off
off
ON
1
2
3 4 5 6 7 8
ON
1
2
3
4
5
6
7
8
Wind reference
CUSTOMER
Operating mode
Wind transmitter type
Baud rate
Wind reference
NACOS