INSTALLATION
Regulations and Standards
In your own interest of safety, gas appliances should be installed by competent persons. Failure
to install the appliance correctly could invalidate any warranty or liability claims. This appliance
shall be installed in accordance with the manufacturers installation instructions, local and state
codes or, in the absence of such codes, with the Standard for Recreational Vehicles,
ANSI
A119.2.
Data label.
The data label is located on the underside of the hob. Ensure that the gas supply is Propane.
This appliance is designed for use with Propane gas
ONLY,
do
NOT
convert for other gases.
Ventilation – All Models
This appliance is suitable for installation into RVs. In all cases the national standards with
regard to ventilation for the particular vehicle into which the appliance is to be installed must be
adhered to.
It is recommended the appliance be installed into an enclosure having a gas escape hole
beneath the appliance. The gas escape hole must
vent to the outside and have a cross-
sectional area between 3 in
2
and 6 in
2
and should be baffled to prevent direct draught to the
appliance.
Location – All Models
This appliance maybe installed in a kitchen/kitchen diner but NOT in a room containing a bath or
a shower. LP gas appliances must not be fitted below ground level. e.g. basement.
A direct distance of 4
1
/
2
in must exist between the edge of appliance and combustible material
unless protected by a layer of non-combustible material – see Appliance Location, page 6
For models with a glass lid, the distance to the rear of the appliance can be reduced to 1
1
/
2
in
This appliance must be positioned free from drafts, which may affect the combustion, and in a
manner that will prevent the accumulation of unburnt gas. When in use ensure that air vents
are not inadvertently blocked or shut off.
The underside of the appliance must be shielded. It is recommended that the shield is fabricated
from non-combustible material, but if the enclosure is manufactured from combustible material,
then a minimum air space of 100mm must exist between the material and the lowest part of the
appliance.
THIS AIR SPACE MUST BE WELL VENTILATED
It is recommended any cupboards located beneath the appliance be sealed to prevent a gas
escape entering the living area.
IMPORTANT – ALL APPLIANCES
•
The maximum depth of overhead cabinets installed above the HOB must
NOT
exceed
13 in – see Appliance Location, page 6. All combustible materials such as curtains
and shelves must be kept well clear of the appliance, and their installation should
meet all relevant local and state regulations/standards in force.
•
30 inches is the
minimum vertical distance to combustible material
above the cooktop.
This distance may be reduced by using non-combustible construction in accordance
with table 5.6.6.5 Vertical Clearances to Combustible Material or Metal Cabinets in
ANSI 119.2 2005.
15
Summary of Contents for Spinflo 160 Series
Page 3: ...3...
Page 4: ...4...
Page 5: ...5...
Page 7: ...WORKTOP CUTOUT DETAILS All dimensions in inches 7...
Page 8: ...WORKTOP CUTOUT DETAILS All dimensions in inches 8...
Page 10: ...10...
Page 21: ...21...
Page 22: ...22 22...
Page 23: ...23...
Page 25: ...DETAILS CONCERNANT LA DECOUPE DU PLAN DE TRAVAIL 25...
Page 26: ...DETAILS CONCERNANT LA DECOUPE DU PLAN DE TRAVAIL 26...
Page 27: ...SERIE 162 167 DETAILS CONCERNANT LA DECOUPE DU PLAN DE TRAVAIL 27...
Page 28: ...28...