![ThermoTex CoziStat Installation Instructions & Operating Manual Download Page 6](http://html1.mh-extra.com/html/thermotex/cozistat/cozistat_installation-instructions-and-operating-manual_1106317006.webp)
Disclaimer: Any information given is believed to be reliable. However, users should treat this information as a guideline, and independently evaluate the suitability of the product for their particular
application. Thermotex Engineering Limited makes no warranties as to the accuracy and completeness of the information and disclaims any liability regarding its use.
Thermotex Engineering Ltd
, 1a Broom Business Park, Broom Bank Road, Chesterfield S41 9QG
T:
+44 (0) 1246 453 769
F:
+44 (0) 1246 454 988
E:
W:
www.thermotex.co.uk
Revision 1.01
C O Z I S T A T I N S T A L L A T I O N I N S T R U C T I O N S & O P E R A T I N G M A N U A L
10
.
Advanced Settings
1. Temperature Compensation in internal sensor
Ensure the Display reads '01 -1'
2. Deadzone Temperature
/ Switching Tolerance
Switch the CoziStat Display OFF. Press and hold both the
and buttons at the same time for approximately 3
seconds to enter the Advanced Settings Menu. The display
should read '01 -1'. Press to change between the
M
enu
O
ption number on the left of the display, and use the up and
down arrow keys to switch between the options on the right
of the display.
See below for explanations of the Menu
Options.
Options: 01
, 02, 03, 04,
05
'
01
'
means that the tolerance will be set to 1
o
C (
'
02
'
means that
the tolerance will be set to 2
o
C, and so on).
A 1
o
C tolerance means that the thermostat will switch the heater
ON when the Room Temperature falls 1
o
C or more below the Set
Temperature. Similarly, the thermostat will switch the heater OFF
when the Room Temperature rises 1
o
C or more above the Set
Temperature.
A 2
o
C tolerance means that the thermostat will switch the heater
ON when the Room Temperature falls 2
o
C or more below the Set
Temperature. Similarly, the thermostat will switch the heater OFF
when the Room Temperature rises 2
o
C or more above the Set
Temperature.
We recommend setting the tolerance at
'
01
'
. To do this e
nsure
the Display reads '0
2
0
1'
.
3
.
Sensor Type
Options:
In, Ou, AL
'
In' refers to the internal sensor in the thermostat. This measures
the room (air) temperature only, not the floor temperature.
'Ou' refers to the external sensor installed in the floor. This
measures the floor temperature only, not the air temperature.
'AL' refers to the internal sensor measuring the room (air)
temperature and the external sensor used to limited the floor
temperature.
Using CoziStat to control underfloor heating, we recommend
you use the external sensor at all times. To do this ensure the
Display reads '03 Ou'.
4
.
Low Temperature Protection
Options: 5, 6, 7, 8, 9, 10, - -
'5' means that low temperature protction is set to 5
o
C. If the
Room Temperature drops below 5
o
C the thermostat will switch
the heating ON to maintain a minimum of 5
o
C. This Low
Temperature Protection Setting can be set to switch the
thermostat ON between 5
o
C and 10
o
C. Select '- -' to cancel the
Low Temperature Protection Setting.
5
.
High Temperature Protection
Options: 35-70*, - -
*DO NOT SET THE HIGH TEMPERATURE PROTECTION
SETTING HIGHER THAN 45 (45
O
C)
'35' means that high temperature protction is set to 35
o
C. If the
Temperature reading rises above 35
o
C the thermostat will
switch the heating OFF to maintain a maximum of 35
o
C. Use this
High Temperature Protection Setting to switch the thermostat
OFF between 35
o
C and 45
o
C.
6
.
Button Locking
Ensure the Display reads '0
6
0
'
7
.
Weekend Setting
Options: 2 day weekend, 1 day weekend, no weekend
'MON TUES WED THURS FRI' displayed across the top of the
screen means a 2 day weekend is selected.
'MON TUES WED THURS FRI SAT' displayed across the top of
the screen means a 1 day weekend is selected.
'MON TUES WED THURS FRI SAT SUN' displayed across the
top of the screen means no weekend is selected (i.e. one
heating programme which is the same every day)