![THERMOSTAHL ECOBIO Installation And User Manual Download Page 21](http://html1.mh-extra.com/html/thermostahl/ecobio/ecobio_installation-and-user-manual_1106261021.webp)
ELECTRICAL CONNECTIONS
21
5.3.8.
Hydraulic scheme
Legend:
1.
Boiler
2.
Regulator (main module)
3.
Display
4.
Boiler temperature sensor
6.
Central heating pump
7.
Thermostatic 3-way valve
8.
Circulation pump
9.
External temperature sensor
10.
Collector
11.
Domestic hot water temperature sensor
12.
Domestic hot water pump
13,18,23,28. Mixer servomotor
14,19,24,29. Mixer pump
17,22,27,31. Mixer temperature sensor
16,21,26,30. Room thermostat of mixer zone
32.
Extension module for mixer
33.
Hot water boiler
The presented hydraulic diagram does not replace the central heating system
design and it can be used for reference purposes only.
The boiler regulator controls the central heating pump and the hot water pump according to the
settings made. A room thermostat can be connected which will decrease the preset boiler
temperature. By means of the external temperature sensor the weather control can be activated,
which will modulate the boiler temperature according the external temperature.
The regulator can be extended with two additional mixing modules (MODULE B-MODULE C),
which enable the control of two mixing zones per module (a total of four mixing zones). Each
mixing module contains a mixer servomotor, a mixer pump, a mixer temperature sensor and a
mixer room thermostat.