Preparation for use

This process must be followed after installation and prior to first use

ThermoSphere Micro Electric Boilers must be primed after installation and before the first use. 

Priming is also required after the electricity supply to the unit has been turned off or removed, for example after a 
power failure or isolation of the electrical supply.

Priming is required to set the unit up for optimal heating ramp-up time and maximum efficiency. A correctly primed 
TSMEB will ramp up to the optimised power required as efficiently as possible without overshoot.

Note: Power overshoot typically occurs in instantaneous water heaters as a result of the maximum output required 
to get a heat exchanger up to working temperature as quickly as possible. However, as TSMEBs do not have a heat 
exchanger the risk of overshoot is greatly reduced because it does not require a power “kick” at start up.

Your ThermoSphere Micro Electric Boiler is now ready for use!

Step 1: Flush

•  Flushing is required to clear the unit of plumbing 

debris that may have collected in the piping during 
installation.

•  This is done with the electric power supply turned off

•  Flush water through the unit.

•  Flushing should be allowed to continue for at least 2 

minutes.

•  After flushing remove the inlet filter from the cold 

water inlet, clean any debris due to installation and 
flushing and refit.

Step 2: Prime

•  Turn the electricity supply on and check the LED is slow flashing 

GREEN

. The unit is now in stand-by mode.

•  Turn on the hot water outlet to a flow rate greater than 1.5 ltr/min. The unit will start heating.

•  Check the LED is fast flashing 

GREEN

 and allow the unit to run for at least 3 minutes before closing the outlet.

Automatic air purging during priming 

 

Depending on the initial flow rate during priming, the unit may not start heating until approximately 1.2 Litres of 
water has cycled through the unit. This is to ensure that any air in the system has been purged. 

You know heating has started as soon as the LED starts fast flashing 

GREEN

. This automatic air purging and priming 

will happen whenever the electrical mains power is turned off, to ensure optimum performance.

Summary of Contents for TSMEB-10

Page 1: ...HEATING WATER MICRO ELECTRIC BOILER Live well INSTALL GUIDE...

Page 2: ...f your work Just scan the QR code or search online for ThermoSphere CONNECT and fill in the form Nice and easy After you sign up instantly start uploading your receipts to gain your rewards Join in 60...

Page 3: ...Installation options 8 Specifications 9 Flow rates 10 Installation procedure 11 Mounting to the wall 12 Electrical terminals and connections 13 Wiring diagrams for single and tandem installations 14 P...

Page 4: ...ThermoSphere Bridge House Pattenden Lane Marden Kent TN12 9QJ United Kingdom hello thermosphere com 0800 0195899 2 The process will then follow the ThermoSphere Product Warranty Flow Chart to assess w...

Page 5: ...eferably be installed in a vertical position on an internal wall or in an internal cupboard or space If the safety rules or the instructions outlined in this manual are not followed correctly the unit...

Page 6: ...g 2 TSMEB Top Cover 13 TSMEB Inlet Filter 3 TSMEB Heat Sink 14 PCB Terminal Block 4 TSMEB Flow Rate Sensor 15 Electric Mains Supply Cable Gland 5 TSMEB Temperature Sensor Receptacle Cable and Plug Ass...

Page 7: ...s or improper use voids the warranty Never remove the unit cover unless the electricity is turned off at the isolation switch or switchboard To reduce the risk of electric shock or injury to persons o...

Page 8: ...ls and labour It also eliminates wasted water and wasted energy by delivering water at the correct temperature within seconds Point of use with cold feeds or mixer taps TSMEBs can be installed to supp...

Page 9: ...d inside only Ambient temperatures 5 C Drain unit if the ambient temperature is likely to drop below 5 C Standards CE Warranty 3 years Electrical specifications Model TSMEB 5 TSMEB 6 TSMEB 7 TSMEB 8 T...

Page 10: ...11 4 6 9 13 8 8 16 9 2 17 25 C 2 8 5 6 3 4 6 8 4 1 8 2 4 8 9 6 5 5 11 35 C 2 4 2 5 5 2 9 5 8 3 4 6 8 3 9 7 8 45 C 1 5 3 1 9 3 8 2 3 4 6 2 7 5 4 3 1 6 2 Flow rates and energy use with input water at 5...

Page 11: ...supplying the 240VAC electrical mains to the TSMEB are turned OFF 7 Carefully replace the plug and cable connecting the display PCB LED indicator to the PCBA 8 Connect a water pressure limiting valve...

Page 12: ...d the mains supply cable gland fitting hole must not be drilled out Any holes drilled within these areas the sides of the unit or opening out the cable gland fitting hole will render the unit inoperab...

Page 13: ...o thermosphere com 13 Electrical terminals and connections 1 2 3 4 5 6 Electric supply cable gland Printed circuit board assembly PCBA Terminal block Display PCB PCBA reset button Display PCB plug and...

Page 14: ...cause an earth leakage detection Error code FC With tandem installations both units must be fitted with their own respective RCBO and an isolation switch in line with the xed wiring to each electrica...

Page 15: ...talled must not be a non return valve If the water heater is supplying a dishwasher or washing machine a water hammer arrestor must be installed on the outlet side of the water heater Water inlet and...

Page 16: ...dy for use Step 1 Flush Flushing is required to clear the unit of plumbing debris that may have collected in the piping during installation This is done with the electric power supply turned off Flush...

Page 17: ...slow or fast flashing GREEN Fast flashing GREEN Unit is operating and water is being heated Flashing RED continuously Irresolvable error and mechanical lockout Unit will no longer operate until the e...

Page 18: ...mal operation No error 01 Fast flashing GREEN Heating normal operation No error N A Solid ORANGE Water conductivity too low No error N A Solid ORANGE In priming mode No error A4 Flashing RED Operating...

Page 19: ...D indicators on the PCB will be illuminated when the unit is in standby running or in error mode 2 Press the PCBA reset button If the RED LED remains either flashing or illuminated and error condition...

Page 20: ...ps showers supplied Incoming water temp C Set water temp C System flushed and primed Single or Tandem install The stock no of the product You can find this on the label under the unit The serial no of...

Page 21: ...0800 019 5899 hello thermosphere com 21 Notes...

Page 22: ...0800 019 5899 hello thermosphere com 22 Notes...

Page 23: ...23 135mm 285mm Installation hole marking template 170mm...

Page 24: ...Thermogroup Ltd Bridge House Pattenden Lane Marden TN12 9QJ E OE Thermogroup Ltd 2022 0800 019 5899 hello thermosphere com www thermosphere com TSMEBIG_1121_v1 2 Live well...

Reviews: