6.
Turn the coupling nut clockwise and tighten to a full stop. The
regulator will seal on the back-check feature in the LP cylinder
valve, resulting in some resistance.
An additional one-half to
three-quarters turn is required to complete the
connection. Tighten by hand only – do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator and
repeat steps 5 and 6. If you are still unable to complete the
connection,
do not use this regulator!
Straig
ht
Hold coupling nut and regulator
as shown for proper connection
to LP cylinder valve.
DANGER
• Do not insert any tool or foreign object into the valve
outlet or safety relief valve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
Leak Testing Valves, Hose and Regulator
1. Turn all grill control knobs to OFF.
2.
Be sure regulator is tightly connected to LP cylinder.
3.
Completely open LP cylinder valve by turning hand wheel
counterclockwise. If you hear a
rushing sound
, turn gas off
immediately. There is a major leak at the connection.
Correct
before proceeding
.
4.
Brush soapy solution onto areas circled below.
5. If “growing”
bubbles appear, there is a leak. Close LP
cylinder valve immediately and retighten connections.
If leaks
cannot be stopped do not try to repair.
Call for replacement
parts. Order new parts by giving the serial, model number and
name and part number of items needed (see parts list) to the
Grill Service Center at 1-888-430-7870.
6.
Always close LP cylinder valve after performing leak test by
turning hand wheel clockwise.
6 • 461262508
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
• If a leak is detected at any time, STOP and call the fire
department.
• If you cannot stop a gas leak,
immediately
close
LPcylinder valve and call LP gas supplier or your fire
department!
WARNING
s
Never remove threaded
orifice at end of valve.