Intervallo modulazione con T max 65°c
61 °c
5
3
4
2
65 °c
1
Potenza di funzionamento
WORK
80 °c
STOP
Auto
62
65
17 : 15
Potenza di funzionamento
Intervallo modulazione con T max 70°c
61 °c
5
4
3
2
1
70 °c
80 °c
STOP
WORK
Auto
63
70
17 : 15
5.9.3
5.9.3
5.9.3
5.9.3
5.9.3 A
A
A
A
AUT
UT
UT
UT
UTOMA
OMA
OMA
OMA
OMATIC OPERA
TIC OPERA
TIC OPERA
TIC OPERA
TIC OPERATING CY
TING CY
TING CY
TING CY
TING CYCLE
CLE
CLE
CLE
CLE
In the automatic operating cycle the generator expresses its maximum flexibility of operation while optimising fuel consumption. To activate
the AUTO cycle, select the power bars until the word AUTO appears. During the AUTO cycle the heater / boiler self-regulates
the combustion according to the water temperature in the boiler set with button (2) . If for example the temperature is set at 70°C the five
speed levels will be automatically distributed between 61°C and 70°C so that with a temperature set at 70°C the heater / boiler is at its
minimum power level. The minimum level can be adjusted by means of button (2). If the value ( ) is increased or reduced by means of
button (2) all the power levels will be redistributed along the full temperature range. We therefore recommend finding the best ( ) in order
to optimise the full potential of the produced heat..
If for example the value is set at a high temperature, let's say 73°C, the appliance will attempt to reach that level as quickly as possible by
modulating the power as it approaches the set temperature. It is not necessary to set high t max temperatures when the ambient conditions
do not require them. Time and experience in using the appliance will give you the possibility of determining which are the most appropriate
SET POINTS for your needs. If the combustion power is not absorbed by the system above a temperature of 80° C the appliance will
temporarily shut down and the word STOP will appear in the display. Reactivation will occur automatically when the temperature drops to
58°C.
13 : 15
SUNOUT
62
65
78
83
SUNOUT: this function only activates automatically if the
THERMOCONTROL setting is set on ON and if Thermosole solar panels
are connected to the Thermocell. If Sensor S2 in the Thermocell detects
a temperature exceeding 85°C in the OFF phase the word SUNOUT
appears on the display accompanied by the pump active indicator and
by the activation of ' smoke suction unit at the maximum power. When
sensor S2 temperature drops to 65°C the word SUNOUT disappears
and is replaced by the word OFF and at the same time the circulator
pump and the smoke suction unit switch off. This guarantees the
dissipation of the excess heat input from the solar panels: situation
occurring during the summer period.
5.9.2 SETTING RANGE
5.9.2 SETTING RANGE
5.9.2 SETTING RANGE
5.9.2 SETTING RANGE
5.9.2 SETTING RANGE
The heat transfer takes place according to the principle of anticondensation, that is by activating the pump at a threshold that, in this specific
case, is 61°C. Activating the pump at a lower threshold would lead to the formation of acid condensation which is harmful for the life of the
generator. The lowest temperature value in the setting range is 61° C.
The maximum temperature possible for selection is 73°C; once this value is exceeded the machine runs at the minimum steady state level.
The STOP phase trips if the 80 °C limit is exceeded.
The maximum temperature can be selected by means of the °C button (2) (see para. 5.1) on the control panel. This temperature can be set
between 65 °C and 73°C. Every time you press the button you will notice the symbol
appear on the screen folowed by the value in figures.
K E Y
Operating power
Intervallo modulazione con Tmax 70C°/ 65°C
LEGENDA
Potenza di funzionamento
Intervallo modulazione con Tmax 70C°/ 65°C