Installation, use and maintenance guide
BOSKY SQUARE 30
– BOSKY SQUARE F30
Page 24
ENG
7.8 PRESCRIPTIONS FOR CORRECT OPERATION
- Respect the maximum declared consumption, do not overload the stove with excessive quantities of fuel as this could cause
damage.
LOADING A LARGER QUANTITY OF FUEL OR LOADING SEVERAL TIMES IN AN HOUR EXPOSES THE
COMPONENTS OF THE APPLIANCE TO VERY HIGH TEMPERATURES. FOR THIS REASON THE WARRANTY
WILL NOT COVER ANY DAMAGE CAUSED BY PROLONGED EXPOSURE OF THE APPLIANCE TO THESE
TEMPERATURES.
DO NOT THROW THE WOOD INTO THE COMBUSTION CHAMBER, PLACE IT IN GENTLY. THROWING THE
WOOD COULD END UP BREAKING PARTS. DAMAGE CAUSED IN THIS WAY IS NOT COVERED BY
WARRANTY
.
- The appliance must not be used as an incinerator, the use of liquid or gaseous fuels is prohibited.
- Adhere strictly to the operating instructions set out in this manual.
- Always verify that the fuel loaded into the combustion chamber lights correctly. Make sure that this always occurs to avoid any
buildup of combustible gases. The buildup of a high quantity of combustible gases could exceed the mechanical resistance of the
glass and other components of the stove. For this reasons the manufacturer disclaims all responsibility.
- In adverse weather conditions, such as for example low pressure, windy or rainy days or days with high outside temperatures, the
effect could be a drop in draught or reverse draught. In these situations the flue gases may not be completely exhausted.
Consequently, in these cases it is necessary to increase the primary air and load the smallest amount of fuel in order to reactivate
the draught of the flue outlet. If you notice the smell of smoke in the room or stagnation of gases inside the combustion chamber
avoid using the appliance.