INSTALLATION
page 16
4.7.1 DIAGRAM OF ASPIROTRONIC LE ELECTRONIC PANEL
11
1
1
33
3
3
22
2
2
4
4
4
4
55
5
5
77
7
7
88
8
8
66
6
6
99
9
9
3 WAY VALVE DIESEL OIL POSITION
3 WAY VALVE WOOD POSITION
COMMON 3 WAY VALVE
ROOM TEMPERATURE THERMOSTAT
PLANT CIRCULATING PUMP
ADDITIONAL CIRCULATING PUMPS
RECYCLING PUMP
GAS-DIESEL OIL BURNER
FAN
N.O.
BY PASS EXCHANGE COM.
N.C.
COMMON BOILER TUBE THERMOSTAT
N.C. BOILER TUBE THERMOSTAT
N.O. BOILER TUBE THERMOSTAT
BOILER TUBE CIRCULATING PUMP
The fuses on the power board are shown in the diagram:
1) 220 V safety fuse
2) General safety fuse
3) 3 way valve fuse
4) By pass fuse
5) Circulating pump fuse
6) Low voltage fuse
7) Recycling pump fuse
8) Burner fuse
9) Smoke suction unit fuse
N.B.: If the room temperature thermostat is not
used install a jumper between terminals 4 and 5
on terminal board M1.
N.B.: If the boiler tube is not used install a
jumper between terminals 1 and 4 on terminal
board M2.